Blood flow measurements at different depths using photoplethysmography and laser Doppler techniques.

BACKGROUND/PURPOSE This study has evaluated a multi-parametric system combining laser Doppler flowmetry and photoplethysmography in a single probe for the simultaneous measurement of blood flow at different depths in the tissue. This system will be used to facilitate the understanding of pressure ulcer formation and in the evaluation of pressure ulcer mattresses. METHODS The blood flow in the...

متن کامل

Tissue blood flow measurement by laser Doppler technique

  Measurement of blood flow and the effects of different factors on tissue blood flow are important fields of research in physiology and pharmacology. So far, different methods have been innovated, using laser light is the Last one. In this article history, principles and specifications of laser technique along with its advantages and disadvantages ( in comparison with other methods) are revie...

متن کامل

Simultaneous recording of skin blood pulsations at different vascular depths by multiwavelength photoplethysmography.

A new technique for parallel recording of reflection photoplethysmography (PPG) signals in a broad spectral band (violet to near-infrared) has been developed, and its potential for assessment of blood microcirculation at various depths from the skin surface is discussed. PPG signals have been simultaneously detected at cw laser wavelength sets comprising 405, 532, 645, 807, and 1064 nm. Various...

متن کامل

Perfusion assessment in rat spinal cord tissue using photoplethysmography and laser Doppler flux measurements.

Animal models are widely used to investigate the pathological mechanisms of spinal cord injury (SCI), most commonly in rats. It is well known that compromised blood flow caused by mechanical disruption of the vasculature can produce irreversible damage and cell death in hypoperfused tissue regions and spinal cord tissue is particularly susceptible to such damage. A fiberoptic photoplethysmograp...

متن کامل

Sound-induced artifact in cochlear blood flow measurements using the laser Doppler flowmeter.

The laser Doppler flowmeter has been shown to give a response from the cochlea during high intensity acoustic stimulation which is not related to blood flow through the cochlea. The magnitude of this response depends upon the intensity and frequency of stimulation and the location of the probe on the cochlea. Evidence is presented that the response is derived from the vibration of cochlear tiss...

متن کامل