Biometric parameters and intra ocular lens power used for cataract eyes in Karnali, Nepal

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biometric parameters and intra ocular lens power used for cataract eyes in Karnali, Nepal.

INTRODUCTION The biometric parameters of the eye are measured for the calculation of the intra ocular lens power to be used in cataract surgery. OBJECTIVE To report the keratometry reading, axial length and intra ocular lens power used for eyes operated for cataract in Karnali Zone, Nepal, and to compare these findings with those reported in other similar studies. SUBJECTS AND METHODS The d...

متن کامل

Intra-ocular lens power calculation in patients with high axial myopia before cataract surgery.

PURPOSE To evaluate the accuracy of different formulas used for IOL power calculation in patients with high axial myopia undergoing cataract surgery. METHODS A prospective clinical study was carried out on 53 eyes of 51 patients with an axial length from 25.5 to 31.4 mm including 21 males (41.2%) and 30 females (58.8%). Calculation of the IOL power to be implanted was done by three available ...

متن کامل

ocular biometric changes after phacotrabeculectomy and its effect on intraocular lens power calculation

purpose: to evaluate ocular biometric changes after phacotrabeculectomy and its effect on intraocular lens power calculation. methods: twenty six eligible eyes (24 patients) underwent phacotrabeculectomy. they were reexamined at least 6 months after the operation in a historical cohort study. main outcome measures included axial length (al) with contact a- scan (us-8000, nidek, gamaguri, japan)...

متن کامل

Intra-Ocular Lenses for Cataract Patients

1989 was the 40th anniversary of intra-ocular lens implantation. Harold Ridley performed the first implant for cataract surgery in November 1949 at St. Thomas' Hospital. The idea developed on the following lines: It was known that trauma from plastic imbedded in the eye was inert, a situation seen mainly in air pilots who had suffered injuries from shattered windscreens. But the seed was sown b...

متن کامل

Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes

PURPOSE We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND METHODS Twenty eyes from 20 patients were enrolled in this study. Modulation transfer function cutoff frequency, The Strehl ratio, objective scatter i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nepalese Journal of Ophthalmology

سال: 2014

ISSN: 2091-0320,2072-6805

DOI: 10.3126/nepjoph.v6i2.11690