Biomechanical Evaluation of a Novel Lisfranc Injury Cadaveric Model Using Supination and Pronation Testing
نویسندگان
چکیده
منابع مشابه
hazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
Impaired pronation-supination of the forearm: an inherited condition.
Davenport, Taylor, and Nelson (1924) have reported several instances of familial radio-ulnar synostoses with variable degrees of reduction in pronation and supination. Their cases fall into three general types: (1) radius without a head; (2) radial head displaced backwards; and (3) radial head more or less normal but radial shaft strongly curved. Cockshott and Omololu (1958) reported a father a...
متن کاملwuthering heights and the concept of marality/a sociological study of the novel
to discuss my point, i have collected quite a number of articles, anthologies, and books about "wuthering heights" applying various ideas and theories to this fantastic story. hence, i have come to believe that gadamer and jauss are rightful when they claim that "the individaul human mind is the center and origin of all meaning," 3 that reading literature is a reader-oriented activity, that it ...
15 صفحه اولA biomechanical analysis of a tensioned suture device in the fixation of the ligamentous Lisfranc injury.
BACKGROUND We hypothesized that using a cadaveric Lisfranc ligamentous injury model, abduction stress would provoke greater post-injury motion than axial weightbearing between the medial cuneiform (MC1) and the base of the second metatarsal (MT2). Second, we hypothesized that both a tensioned suture-button device and a rigid screw fixation method could maintain a reduction and similarly restrai...
متن کاملBiomechanical evaluation of a novel cervical spine posterior fixation technique using C1 arch screws: An in-vitro cadaveric stu
INTRODUCTION: The complex anatomy and biomechanics of the atlanto-axial motion segment impose technical challenges in the achievement of safe and successful surgical stabilization and fusion. The coauthors have recently reported successful clinical results using a novel C1-C2 stabilization technique employing C1 multi-axial posterior arch screws (MA-PAS) in a series of 3 patients (see Fig.1a-c)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Foot & Ankle Orthopaedics
سال: 2019
ISSN: 2473-0114,2473-0114
DOI: 10.1177/2473011419s00430