Biomechanical comparison of tenodesis reconstruction for subtalar instability: a finite element analysis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Evaluation and Comparison of the Artificial and Natural Skin Properties Using Finite Element Method

Introduction: The self-repair process cannot occur in the skin lesions, therefore, skin replacements are used due to the formation of a scar, which resulted in the complete loss of skin. Artificial skin should have the same specifications as the natural skin. The finite element methods were used in this study to evaluate the biomechanichal properties of natural and artificial skins. Materials ...

متن کامل

Finite Element Instability Analysis of the Steel Joist of Continuous Composite Beams with Flexible Shear Connectors

Composite steel/concrete beams may buckle in hogging bending regions. As the top flange of I-beam in that arrangement is restricted from any translational deformation and twist, the web will distort during buckling presenting a phenomenon often described as restricted distortional buckling. There are limited studies available in the literature of restricted distortional buckling of composite st...

متن کامل

A New Stress Based Approach for Nonlinear Finite Element Analysis

This article demonstrates a new approach for nonlinear finite element analysis. The methodology is very suitable and gives very accurate results in linear as well as in nonlinear range of the material behavior. Proposed methodology can be regarded as stress based finite element analysis as it is required to define the stress distribution within the structural body with structural idealization a...

متن کامل

Biomechanical Analysis of a Three Dimensional Finite Element Model

Low back pain has for long been associated with the lumbar spine biomechanics. A three dimensional model of segments L2 to L5 of lumbar spine is generated form CT images of a healthy human male. Hounsfield units of the image slices are used to derive material properties throughout the 3D model. This model is subjected to finite element analysis to study stresses developed during naturally found...

متن کامل

Biomechanical comparison of the K-ROD and Dynesys dynamic spinal fixator systems - a finite element analysis.

Dynamic spinal fixators, such as the Dynesys (DY) and K-ROD (KD) systems, are designed to restore spinal stability and to provide flexibility. The long-term complications of implant breakage and the biomechanics of the adjacent and the bridged levels using the KD system are still unknown. Therefore, this study aims to investigate and compare the biomechanical effects of the KD system and the DY...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BMC Musculoskeletal Disorders

سال: 2020

ISSN: 1471-2474

DOI: 10.1186/s12891-020-03693-5