Biolimus A9 polymer-free coated stents in high bleeding risk patients undergoing complex PCI: evidence from the LEADERS FREE randomised clinical trial
نویسندگان
چکیده
منابع مشابه
Biolimus-A9 polymer-free coated stent in high bleeding risk patients with acute coronary syndrome: a Leaders Free ACS sub-study
Aims Although a true clinical challenge, high bleeding risk patients with an acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI) have never been specifically studied. Leaders Free ACS, a pre-specified Leaders Free sub-study, determined efficacy, and safety of a combination of 1-month dual anti-platelet therapy (DAPT) with implantation of either a polymer-free Bioli...
متن کاملEarly Clinical Experience with a Polymer-Free Biolimus A9 Drug-Coated Stent in DES-Type Patients Who Are Poor Candidates for Prolonged Dual Anti-Platelet Therapy
INTRODUCTION Prolonged dual anti-platelet therapy (DAPT) may cause excess bleeding in certain patients. The biolimus-A9 drug-coated stent (BA9-DCS) has a rapid drug-elution profile allowing shortened DAPT. Data were gathered on the early experience implanting this stent in drug-eluting stent eligible patients deemed to be at high risk of bleeding. BACKGROUND AND METHODS The demographics, proc...
متن کاملPolymer-Free Biolimus A9-Coated Stents in the Treatment of De Novo Coronary Lesions: 4- and 12-Month Angiographic Follow-Up and Final 5-Year Clinical Outcomes of the Prospective, Multicenter BioFreedom FIM Clinical Trial.
OBJECTIVES The purpose of this study was to evaluate the efficacy and long-term outcomes of a novel polymer/carrier-free drug-coated stent (DCS) in patients with de novo coronary lesions. BACKGROUND The BioFreedom (BFD) DCS incorporates a low-profile, stainless-steel platform, with a surface that has been modified to create a selectively microstructured abluminal surface that allows adhesion ...
متن کاملCompounding the Bleeding Reduction Effects of Transradial PCI and Bivalirudin in a High-Risk Patient Undergoing Complex PCI
متن کامل
Clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents
There are limited data about clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents (BP-BES) and durable polymer everolimus-eluting Xience stents (DP-EES) in real world practice. We sought to compare the clinical outcomes of BP-BES and DP-EES in real world cohorts of patients undergoing percutaneous coronary intervention. A prospective multicenter registry enrolled 999 pat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: EuroIntervention
سال: 2018
ISSN: 1969-6213
DOI: 10.4244/eij-d-18-00293