Coiled tubing corrosion was investigated for 16 field water samples (S5 to S20) from a Canadian shale gas field. Weight loss corrosion rates of carbon steel beads incubated with these field water samples averaged 0.2 mm/yr, but injection water sample S19 had 1.25±0.07 mm/yr. S19 had a most probable number of zero acid-producing bacteria and incubation of S19 with carbon steel beads or coupons d...

متن کامل

Control of corrosion in oil and gas production tubing

L. SMITH Controlling corrosion in production tubing is essential for maintaining production and for preventing loss of well control. Materials for use downhole have to meet criteria for corrosion resistance and also mechanical requirements. The potential corrosion rate can be estimated and the risks of sulphide stress corrosion cracking assessed on the basis of the anticipated environmental con...

متن کامل

Integration of distributed strain and temperature sensors in composite coiled tubing

Composite coiled tubing is an emerging technology in the oil & gas sector that presents important advantages compared to the steel coiled tubing and conventional drilling. The composite tube has reduced weight, allowing extended reach and improved fatigue life. An additional advantage resides in the fact that the coiled tube wall can contain and protect additional functional elements, such as e...

متن کامل

Finite Element Based Dynamic Analysis of a Device in Coiled Tubing Drilling

The need for flexibility in operation and minimized drill time has necessitated the extended use of coiled tubing drilling technology. Among others, the technology eliminates the time to connect drill pipes and thus enables a quick retraction and insertion of different tools in the well. On the other hand, the complexity of the operating conditions makes the task of testing functionality of com...

متن کامل

Ginger extract as green biocide to control microbial corrosion of mild steel

In latest years, various techniques and chemicals have been used for the control of microbial influenced corrosion (MIC) of metals. The application of botanical-based biocides is one of the effective and practical techniques in the fight against MIC. In the present study, the role of aqueous extract of ginger (Zingiber officinale) (GIE) as green biocide to control MIC of mild steel 1010 (MS) in...