Bilirubin interference with uric acid assay in a Hycel: a look at azino uric acid.
نویسندگان
چکیده
منابع مشابه
A new automated uric acid assay.
Currently, the most popular automated method for the determination of serum uric acid is the automated method modified by Musser and Ortigoza (1966) for the TechniconS AutoAnalyzer system. While this method is considered reliable, it suffers from the following deficiencies: (a) it shows non-linearity with dilutions of aqueous uric acid standards and is thus dependent on costly reference sera as...
متن کاملSerum Uric Acid as a Potential Concomitant with Carotid Atherosclerosis
Background: Common carotid intima-media thickness (CC-IMT) measured by ultrasonography as a non-invasive method is nowadays known as a marker for early atherosclerosis. Objectives: Survey the relationship between serum uric acid and carotid intima-media thickness considering hypertension. Materials and Methods: This study was designed as a comparative cross-sectional study in northern Ira...
متن کاملImproved uric acid assay in the Paramax.
acid was observed. Analytical recoveries of added etofena. mate and flufenamic acid, respectively, at concentrations of iO, 10-6, and i0 mol/L each exceeded 95%. The detection limit for each was 5 10_8 mol/L. This method can also be used to determine etofenamate and fiufenaniic acid in the synovial liquid. Tissue. We injected, intraperitoneally, 1.48 mg of etofenamate in 1 mL of equal volumes o...
متن کاملA simplified alkaline phosphotungstate assay for uric acid in serum.
An alkaline phosphotungstate procedure was developed in which the phosphotungstic acid reagent is used both as protein-precipitating and oxidizing reagent. The procedure requires only a 0.2-mi sample and fewer reagents and manipulations than similar procedures, but yields results equivalent to those obtained by Henry’s alkaline phosphotungstate procedure. Recovery, precision, and linearity were...
متن کاملUric Acid Analysis with Uricase
Results with two ultramicro methods for plasma uric acid analysis with uricase are described: a crystal violet (gentian violet) method, modified from an automated procedure by Gochman and Schmitz [C/in. Chem. 17, 1154 (1971)] and adapted to manual analysis, and a polarographic oxygen-sensing system (Beckman Instruments,Inc.).The coefficientof variation (CV) for the crystal violet method varied ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry
سال: 1984
ISSN: 0009-9147,1530-8561
DOI: 10.1093/clinchem/30.4.584