Bilateral misplaced three piece posterior chamber intraocular lens in anterior chamber with cystoid macular edema
نویسندگان
چکیده
منابع مشابه
Postsurgical Cystoid Macular Edema following Posterior Chamber Toric Phakic Intraocular Lens Implantation Surgery: A Case Report
PURPOSE To describe a case of cystoid macular edema (CME) developing after posterior chamber toric phakic intraocular lens (PIOL) implantation. METHODS Case report. RESULTS A 33-year-old male underwent implantation of toric implantable collamer lenses (ICL), a new generation of PIOLs, for both eyes. Preoperative best spectacle-corrected distance visual acuity (BCVA) was 20/25 in the right e...
متن کاملdiscrepancy between actual and theoretical anterior chamber depth in patients with morcher posterior chamber intraocular lens
purpose : cataract surgery is the most common ocular surgery worldwide and in modern era of phacoemulsification with posterior chamber intraocular lens (pc iol) implantation, refractive aspects of surgery is as important as the surgery itself. after the iol implantation, the anterior chamber depth (acd) is increased and the iridiocorneal angle is widened. these changes should be considered for ...
متن کاملthe effect of phacoemulsification with posterior chamber intraocular lens implantation on intraocular pressure and anterior chamber depth
purpose : to evaluate intraocular pressure (iop) and anterior chamber depth (acd) change after phacoemulsification with posterior chamber intraocular lens implantation methods : in this quasi-experimental study, 84 patients with senile cataract were included. all patients had normal iop. patients with traumatic and complicated cataract, any history of uveitis, glaucoma, or other ocular disease ...
متن کاملstory dislocated Posterior chamber intraocular Lens Management
P osterior chamber intraocular lenses (IOLs) are exquisitely engineered to provide excellent vision when implanted into a stable capsule following extracapsular cataract extraction. If the lens capsule or the supporting lens zonules fail, and the IOL dislocates, vision usually deteriorates. Unfortunately, just as cars are not designed to be easily fixed after crashing, IOLs are not designed to ...
متن کاملThe Effect of Phacoemulsification with Posterior Chamber Intraocular Lens Implantation on Intraocular Pressure and Anterior Chamber Depth
Purpose: To evaluate intraocular pressure (IOP) and anterior chamber depth (ACD) change after phacoemulsification with posterior chamber intraocular lens implantation Methods: In this quasi-experimental study, 84 patients with senile cataract were included. All patients had normal IOP. Patients with traumatic and complicated cataract, any history of uveitis, glaucoma, or other ocular disease or...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Ophthalmology
سال: 2013
ISSN: 0301-4738
DOI: 10.4103/0301-4738.97561