Bidirectional Short-Circuit Current Blocker for DC Microgrid Based on Solid-State Circuit Breaker

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Efficient Solid State Circuit Breaker for Low Voltage Circuit Protection

The general trend in electrical appliances is to go for electrical equivalents of mechanical or electromechanical gadgets. One of the long standing electronic component is the circuit breaker, a protective device that trips the ac supply once the current through the system goes beyond the rated value. In this paper an all electronic circuit breaker using bidirectional switch is demonstrated. Th...

متن کامل

A New Circuit Topology for Open Circuit and Short Circuit Fault Tolerant Dc - Dc Converter

This paper describes a new design for a fault tolerant Hbridge dc-dc converter. Open circuit and short circuit fault tolerance is achieved using multilevel converter topology in combination with pulse width modulation control strategy allowing a large set of converter switching states to produce bidirectional power flows at any required output voltage. If two switches fail at particular instant...

متن کامل

Solid-State Circuit Breakers For Medium Voltage

How can the large power needs of future electric ships for propulsion, radar, and weapons systems be met given the prohibitive size and weight of the required number of standard 60 Hz AC generators and transformers? A solution may lie in a rugged, efficient, and compact solid-state, 10-20 kV Medium Voltage DC (MVDC) circuit breaker (Figure 1). In this paper, Diversified Technologies, Inc. will ...

متن کامل

Power system monitoring based on relay and circuit breaker information

In this paper we develop monitoring schemes that are able to detect and identify failures in power transmission lines by analyzing binary status information from relays and circuit breakers. The approach, which is based on Petri net models, requires very simple calculations (linear checks) during execution time and allows for concurrent/incremental processing of the information as it arrives at...

متن کامل

Multiprocessor Based Architecture for Controlled Switching of Circuit Breaker

Circuit Breaker is one of the most critical elements of power industry. Controlled Switching of grid voltage and grid current is the best solution to prevent the high inrush current and over voltages. This paper describes the Controlled Switching of Circuit Breaker by using multiprocessor based architecture. With this architecture early detection of most of major fault is feasible; it is also p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Electronics

سال: 2020

ISSN: 2079-9292

DOI: 10.3390/electronics9020306