Bicarbonate Interference with Chloride-Ion-Selective Electrodes
نویسندگان
چکیده
منابع مشابه
Bicarbonate interference with chloride-ion-selective electrodes.
echocardiography. All attending phy-sicians/cardiologists were blinded to the BNP results. To determine the diagnostic accuracy of the two assays for CHF, we performed ROC plot analysis, and areas under the curve (AUC) were calculated for both BNP assays. Comparisons between AUC were assessed according to the method of Hanley and McNeil (10). Cutoff values for the two methods were determined at...
متن کاملDetermination of sodium with ion-selective electrodes.
The advent of ion-selective electrodes made possible the potentiometry of sodium in serum and plasma. These methods were based on dilution of serum, as done in flame photometry, and the results were identical. Analysis of whole blood precludes dilution and so "direct" potentiometry was developed. Results by this technique are variable but tend to compensate for the spurious hyponatremias found ...
متن کاملApplications of Ion Selective Electrodes
Enzyme sensor for organophosphorus insecticides organophosphorus hydrolase in a polymer membrane on a pH sensor is used to catalyse the hydrolysis of compounds with phoshate ester functionality. The detected [H+] change is proportional to the concentration of the phosphate ester insecticide. This is a good example of the use of an enzyme to give selectivity to a specific class of compounds. Unf...
متن کاملIon Activity Scales for Use with Selective Ion-sensitive Electrodes
The development of a variety of selective ion-sensitive electrodes focuses attention on numerical scales for the activity of individual ionic species, for these electrodes measure the activity of the selected ion only relative to that of the same species in a reference solution of known or assigned ion activity. Nevertheless, scales of ion activity must be based on a convention from outside the...
متن کاملActivity and interference effects in measurement of ionized calcium with ion-selective electrodes.
We assessed the magnitude of the errors in ionized-calcium measurements resulting from changes in electrolyte composition for three different ion-selective electrodes: the Orion Model 93-20, the Radiometer F2112, and the Simon neutral carrier membrane electrode. We attempted to distinguish between errors arising from changes in calcium ion activity and those due to interferences in the electrod...