Bi-level Drainage System Design considering Upward Leakage from Semi-impermeable Barrier

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comment on the paper `̀ An analytical solution for design of bi - level drainage systems ' ' by A .

The hierarchy of models applicable to transient free surface problems of ground water ̄ow to drains is discussed. The model choice is related to drain type and dewatering stage. Flow pattern is illustrated to vary with decrease of the water table. Simulation of drains and corresponding boundary conditions are discussed. # 2000 Elsevier Science B.V. All rights reserved.

متن کامل

An analytical solution for bi-level drainage design in the presence of evapotranspiration

The linearized Boussinesq equation incorporating the effect of evapotranspiration with appropriate initial and boundary conditions was solved analytically to predict a fall in the water table in a bi-level drainage system. It was assumed that the evapotranspiration rate decreases linearly with a reduction in the elevation of the water table above the drains. A special case of this solution (i.e...

متن کامل

Use of piezometers to find the depth to impermeable layer in the design of drainage systems

A piezometric head method is proposed to estimate the impermeable layer depth used in drain spacing formulae. The method was tested and compared with soil texture changes and the US Bureau of Reclamation (USBR, 1978) criterion of impermeable layer being one with hydraulic conductivity one tenth to one fifth that of the weighted hydraulic conductivity of the upper layers. The proposed method, wh...

متن کامل

Considering Testability during High-level Design

Considering testability during the early stages of the design flow can have several benefits, including significantly improved fault coverage, reduced test hardware overheads, and reduced design iteration times. This paper presents an overview of high level design methodologies that consider testability during the early (behavior and architecture) stages of the design flow,and their testability...

متن کامل

Privacy Level Indicating Data Leakage Prevention System

As private information can be contained in the DLP (Data Leakage Prevention) system’s target of monitoring, the monitoring process inevitably violates privacy of the internal employees. Currently, existing DLP systems do not consider the privacy violation during the monitoring process. In this work, we are proposing a DLP system considering privacy violation level. The privacy violation level o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Irrigation & Drainage Systems Engineering

سال: 2015

ISSN: 2168-9768

DOI: 10.4172/2168-9768.s1-004