Best PEEP trials are dependent on tidal volume
نویسندگان
چکیده
منابع مشابه
Higher PEEP , Low Tidal Volume Didn ’ t Lower Mortality
A update of the lung cancer staging system probably was long overdue because the old system was based on patients treated with surgery alone. And with greater numbers of patients with which to make staging classifications, the process of developing the staging system “has changed irrevocably,” according to Dr. Peter Goldstraw at the annual meeting of the Society of Thoracic Surgeons. The curren...
متن کاملMinimal PEEP may be "best PEEP".
1 Poe RH, Israel RH, Martin MG, et al. Utility of fiberoptic bronchoscopy in patients with hemoptysis and nonlocalizing chest roentgenogram. Chest 1988; 92:70-75 2 Vidal R, Ruiz J. Aumenta Ia tuberculosis en Espa#{241}a?.Med Clin (Barc) 1986; 86:845-47 3 World Health Organization. Magnitude of tuberculosis problem in the world. WHO Wkly Epidem Rec 1981; 50:17-20,33-36,4951,68-76 and 391-96 4 Gr...
متن کاملLow tidal volume, high respiratory rate and auto-PEEP: the importance of the basics
Recent studies have shown that application of the ARDSNet low tidal volume strategy (i.e. allowing an increase in respiratory rate in order to minimize hypercapnia in those with low tidal volume) may generate consistent auto-PEEP (positive end-expiratory pressure), and this is not efficient in improving clearance of carbon dioxide. The present commentary deals with some of the recent controvers...
متن کاملLow intraoperative tidal volume ventilation with minimal PEEP and postoperative morbidity and mortality.
Editor—In a retrospective single-centre study including 29 343 adult patients undergoing general non-cardiac surgeries under general anaesthesia, Levin and colleagues showed that intraoperative mechanical ventilation using low tidal volumes with minimal PEEP was associated with worse 30 day mortality and an increased hospital length of stay. The strengths of this study include a large sample of...
متن کاملLow intraoperative tidal volume ventilation with minimal PEEP is associated with increased mortality.
BACKGROUND Anaesthetists have traditionally ventilated patients' lungs with tidal volumes (TVs) between 10 and 15 ml kg(-1) of ideal body weight (IBW), without the use of PEEP. Over the past decade, influenced by the results of the Acute Respiratory Distress Syndrome Network trial, many anaesthetists have begun using lower TVs during surgery. It is unclear whether the benefits of low TV ventila...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Critical Care
سال: 2018
ISSN: 1364-8535
DOI: 10.1186/s13054-018-2047-4