منابع مشابه
A fiber optic sensor for measuring glucose in aqueous solutions
In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...
متن کاملFiber-optic bend sensor using LP21 mode operation.
A novel fiber-optic bending sensor based upon the propagation of LP21 mode is demonstrated. The sensor, comprised of an S-bend fiber on an elastic film, measures LP21 mode specklegram rotation, which increments linearly with bending angle by the stress-optic effect. The sensor is capable of experimentally achieving a sensitivity as high as 4.13 rad/m(-1). The theoretical analysis of the sensor,...
متن کاملA shear and plantar pressure sensor based on fiber-optic bend loss.
Lower-limb complications associated with diabetes include the development of plantar ulcers that can lead to infection and subsequent amputation. While we know from force-plate analyses that medial/lateral and anterior/posterior shear components of ground-reaction forces exist, little is known about the actual distribution of these stresses during daily activities or about the role that shear s...
متن کاملFiber-optic bend sensor based on a section of double-cladding fiber
A fiber-optic structure based on a section of a double-clad fiber with depressed inner cladding is investigated for bend sensing. The structure is formed by splicing a section of SM630 fiber between two standard fibers SMF-28. The operation principle relies on the sensitivity of cladding modes that are induced at a splice of fibers having different refractive index profiles. The transmission sp...
متن کاملfMRI-Compatible Registration of Jaw Movements Using a Fiber-Optic Bend Sensor
A functional magnetic resonance imaging (fMRI)-compatible fiber-optic bend sensor was investigated to assess whether the device could be used effectively to monitor opening and closing of the jaw during an fMRI experiment at 3 T. In contrast to surface electromyography, a bend sensor fixed to the chin of the participant is fast and easy to use and is not affected by strong electromagnetic field...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series A
سال: 1999
ISSN: 0387-5008,1884-8338
DOI: 10.1299/kikaia.65.106