Behaviour of stiffened extended shear tab connections under gravity induced shear force
نویسندگان
چکیده
منابع مشابه
Design of Unstiffened Extended Single-Plate Shear Connections
Extended single-plate shear connections (Figure 1) offer many advantages that simplify the construction process. Because the connection to the supported member is moved clear of the support, coping of the supported member is not required and the only fabrication process required for the supported member is drilling or punching. Also, because bolted connections are only used in the connection to...
متن کاملNon-Linear Behavior and Shear Strength of Diagonally Stiffened Steel Plate Shear Walls
In this study, non-linear behavior of diagonally stiffened steel plate shear walls as a seismic resisting system has been investigated, and theoretical formulas for estimating shear strength capacity of the system have been proposed. Several validated analytical finite element models of steel shear walls with various stiffener dimensions are generated to verify and compare the analytical and th...
متن کاملAnalysis of Shear Bands in Sand Under Reduced Gravity Conditions
The strength of granular material, specifically sand is of pivotal importance for understanding physical phenomena on other celestial bodies. However, relatively few experiments have been conducted to determine the dependence of strength properties on gravity. In this work, we experimentally investigated three measures of strength (peak, confined flow, and unconfined flow friction angle) in Ear...
متن کاملFabrication and Characterization of Magneto-Rheological Shear-Stiffened Elastomers
1 School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, Wollongong, NSW, Australia 2 School of Electrical, Computer and Telecommunications Engineering, University of Wollongong, Wollongong, NSW, Australia 3 ARC Centre of Excellence for Electromaterials Science, Innovation Campus, University of Wollongong, Wollongong, NSW, Australia 4 School of Mechanical and Ele...
متن کاملBehaviour of Corroded Stud Shear Connectors under Fatigue Loading
Experimental investigation was conducted on corroded composite push-out specimens to study the behavior of shear studs subjected to fatigue loading. A total of eight standard EC4 push-out specimens were tested. The expected corrosion rate of test specimens ranged from 0 to 50%. The main purpose of these tests was to determine the fatigue life and the reduction effect caused by the corrosion on ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Constructional Steel Research
سال: 2018
ISSN: 0143-974X
DOI: 10.1016/j.jcsr.2018.06.011