Behaviour of continuous reinforced concrete floor slabs subjected to different compartment fires
نویسندگان
چکیده
منابع مشابه
Behaviour of fibre reinforced concrete slabs
This paper presents a comparison of the properties of concrete slabs when two types of fibres are added. One specimen had no fibres and acted as a control specimen. The remaining four specimens had steel and polypropylene fibres added in the volumetric ratio of 0.5% and 1.0%. The dimensions of the slab specimens were 820×820×80 mm and were supported by four rollers at their edges. A displacemen...
متن کاملConcrete Floor Slabs on Grade Subjected to Heavy Loads
Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 1Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
متن کاملInvestigation of structural behaviour of GFRP reinforced concrete deck slabs through NLFEA
This paper presents a numerical study of the structural behaviour of concrete bridge deck slabs under static patch loads and dynamic traffic loads and an investigation of compressive membrane action (CMA) inside slabs. Those deck slabs were reinforced with Glass Fibre Reinforced Polymer (GFRP) bars. Non-linear finite element analysis (NLFEA) models were established using ABAQUS 6.10 software pa...
متن کاملStructural analysis of reinforced concrete chimneys subjected to uncontrolled fire
We studied the behavior and residual structural capacity of reinforced concrete chimneys subjected to an uncontrolled fire. We used a combination of a heat transfer finite element model – to obtain the temporal distributions of temperature during the fire event – and the structural model of concrete chimney design provided by the American Concrete Institute (ACI 307–08). This approach allows es...
متن کاملStructural Consideration in Design of Reinforced Concrete Slabs with Openings
Over 90% of framed structures in Uganda are built from reinforced concrete. Prior to the 1990’s, most buildings had no openings in slabs, yet in city centers buildings butt against each other with widows at front and back only. This limited retail activities to front rooms of the ground floor and the buildings had to be narrow. A baseline survey of 50 shopping malls in Kampala Central Business ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2019
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2019.109445