Behaviour of combined channel/angle connections to tubular columns under monotonic and cyclic loading
نویسندگان
چکیده
منابع مشابه
Mathematical Modeling of Column-Base Connections under Monotonic Loading
Some considerable damage to steel structures during the Hyogo-ken Nanbu Earthquake occurred. Among them, many exposed-type column bases failed in several consistent patterns, such as brittle base plate fracture, excessive bolt elongation, unexpected early bolt failure, and inferior construction work, etc. The lessons from these phenomena led to the need for improved understanding of column base...
متن کاملAnalytical and Experimental Investigation of I Beam-to-CFT Column Connections under Monotonic Loading (RESEARCH NOTE)
In this study, the behavior characteristics of I beam-to-concrete filled tube (CFT) column connection is studied through experiment and finite element models under the monotonic loading. To validate the finite element modeling, at first, an experimental model is made and experimented. After validation of the finite element modeling, different models were created in the software. The studied par...
متن کاملmathematical modeling of column-base connections under monotonic loading
some considerable damage to steel structures during the hyogo-ken nanbu earthquake occurred. among them, many exposed-type column bases failed in several consistent patterns, such as brittle base plate fracture, excessive bolt elongation, unexpected early bolt failure, and inferior construction work, etc. the lessons from these phenomena led to the need for improved understanding of column base...
متن کاملConcrete Filled Tubular Bracing Subjected to Cyclic Loading
The energy absorption of concrete filled, hollow-steel bracing was analyzed respect to geometric and mechanical parameters including the width-to-thickness section ratio, slenderness level, and strength of the steel and concrete. Local buckling and ductility were also investigated with respect to variation in the cross-section. The infill increased the compression resistance, even after multipl...
متن کاملBehaviour of FRP strengthened concrete columns under eccentric compression loading
This paper presents results of testing eccentrically loaded columns externally wrapped with two types of materials. Six cylindrical (205 mm diameter and 925 mm height) plain columns were cast and tested. Half of the columns were wrapped with GFRP and the other half with CFRP. All columns were tested by applying an axial load at 50 mm eccentricity. In each group (GFRP or CFRP wrapped) of columns...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2010
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2010.02.008