Behaviour of CFRP strengthened CHS members under monotonic and cyclic loading
نویسندگان
چکیده
منابع مشابه
Structural behaviour of RC beams externally strengthened with FRP sheets under fatigue and monotonic loading
This paper presents experimental research on the fatigue and post-fatigue static behaviour of reinforced concrete beams strengthened with glass or carbon fibre reinforced polymer (FRP) sheets placed either vertically or obliquely. All beams for fatigue tests were subjected to four-point bending for one million cycles with a frequency of 5 Hz. The results show that the FRP sheets can be used to ...
متن کاملBehaviour of FRP strengthened concrete columns under eccentric compression loading
This paper presents results of testing eccentrically loaded columns externally wrapped with two types of materials. Six cylindrical (205 mm diameter and 925 mm height) plain columns were cast and tested. Half of the columns were wrapped with GFRP and the other half with CFRP. All columns were tested by applying an axial load at 50 mm eccentricity. In each group (GFRP or CFRP wrapped) of columns...
متن کاملAnalysis of Concrete Bridge Girders Strengthened with Cfrp Laminates under Service and Extreme Loading Conditions
Externally bonded carbon fiber reinforced polymer (CFRP) laminates are a feasible and economical alternative to traditional methods for strengthening and stiffening deficient reinforced concrete and prestressed concrete girders as shown in Fig. (1). Although extensive research has already been undertaken to investigate the behavior of CFRP strengthened bridge girders, the majority of work condu...
متن کاملCyclic and Monotonic Behavior of Strengthened and Unstrengthened Square Reinforced Concrete Columns
The use of composite materials is an effective technique to enhance the capacity of reinforced concrete columns subjected to the seismic loading due to their high tensile strength. In this paper, numerical models are developed in order to predict the experimental behavior of square reinforced concrete columns strengthened by glass fiber reinforced polymer and steel bars and unstrengthened colum...
متن کاملMathematical Modeling of Column-Base Connections under Monotonic Loading
Some considerable damage to steel structures during the Hyogo-ken Nanbu Earthquake occurred. Among them, many exposed-type column bases failed in several consistent patterns, such as brittle base plate fracture, excessive bolt elongation, unexpected early bolt failure, and inferior construction work, etc. The lessons from these phenomena led to the need for improved understanding of column base...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Composite Structures
سال: 2019
ISSN: 0263-8223
DOI: 10.1016/j.compstruct.2019.04.029