منابع مشابه
Behavior of Tilted Angle Shear Connectors.
According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors. The application of angle shear connectors in tilted positions is of interest in this study. This study investigates the behaviour of tilted-shaped angle...
متن کاملShear Capacity of C-Shaped and L-Shaped Angle Shear Connectors
This paper investigates the behaviour of C-shaped and L-shaped angle shear connectors embedded in solid concrete slabs. An effective finite element model is proposed to simulate the push out tests of these shear connectors that encompass nonlinear material behaviour, large displacement and damage plasticity. The finite element models are validated against test results. Parametric studies using ...
متن کاملNumerical Investigation of Effect of Rock Bolt Angle on Shear Behavior of Rock Bridges
In this work, the effect of rock bolt angle on the shear behavior of Rock Bridges is investigated using the particle flow code in two dimensions (PFC2D) for three different Rock Bridge lengths. Firstly, the calibration of PF2D is performed to reproduce the gypsum sample. Then the numerical models with the dimensions of 100 mm * 100 mm are prepared. The Rock Bridge is created in the middle of th...
متن کاملBehaviour of Corroded Single Stud Shear Connectors
In this study, the effect of corrosion on the static behavior of stud shear connectors was investigated. An innovative test setup for single stud shear connectors was designed and established. Two series of specimens having different stud diameters were fabricated and tested. The test specimens were firstly corroded to different corrosion rates by the electronic accelerating method. Static load...
متن کاملAnalysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure
Shear connectors are used in steel beam-concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: PLOS ONE
سال: 2015
ISSN: 1932-6203