BEHAVIOR OF STRIP FOOTING ON REINFORCED SAND SLOPE
نویسندگان
چکیده
منابع مشابه
Bearing capacity of shell strip footing on reinforced sand
In this paper, the ultimate load capacities of shell foundations on unreinforced and reinforced sand were determined by laboratory model tests. A series of loading tests were carried out on model shell footing with and without single layer of reinforcement. The tests were done for shell foundation at different shell embedment depth and subgrade density. The results were compared with those for ...
متن کاملStudy of bearing capacity of strip footing resting on reinforced sand
This research was performed to investigate the behavior of strip footing on geosynthetic reinforced sandy soil and to study the effect of different parameters contributing to their performance using laboratory model tests. The parameters investigated in the study included top layer spacing (u), width of reinforcement (b), vertical spacing between layers (s) and number of reinforcement layers (N...
متن کاملstrip footing behavior on reinforced sand with void subjected to repeated loading
this paper describes a series of laboratory model tests on strip footings supported on unreinforced and geogrid-reinforced sand with an inside void. the footing is subjected to a combination of static and cyclic loading. the influence of various parameters including the embedment depth of the void, the number of reinforcement layers, and the amplitude of cyclic load were studied. the results sh...
متن کاملEccentrically loaded strip foundation on geogrid-reinforced sand
Results are presented for laboratory model tests conducted to determine the ultimate bearing capacity of an eccentrically loaded strip foundation supported by geogridreinforced sand. Only one type of sand at one relative density of compaction and one type of geogrid were used for the tests. The depth of the foundation was varied from zero to B (width of foundation). Based on the laboratory test...
متن کاملbehavior investigation of reinforced and unreinforced sand below strip foundation using piv
in this research, failure mechanism, soil deformation and effect of reinforcement below a strip foundation were studied using physical modeling and piv method. for this purpose, a comprehensive set of tests were undertaken on dense and loose sands and different geosynthetic materials such as geotextile and geogrid for soil reinforcing. in each step of loading, digital image of deformed soil was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Civil Engineering and Management
سال: 2015
ISSN: 1392-3730,1822-3605
DOI: 10.3846/13923730.2014.890646