Unbonded Post Tensioned Concrete Slabs in Fire – Part II – Modelling Tendon Response and the Consequences of Localized Heating
This is Part II of a two part paper dealing with the current state of knowledge of the fire-safe structural design and construction of unbonded post-tensioned (UPT) flat plate concrete structures. Part I provided detailed results of nineteen transient high temperature stress relaxation tests on restrained UPT tendons of realistic length and parabolic longitudinal profiles. Experimentation ident...
متن کاملPunching strength of actual two-way slabs
Many building codes rely on empirical formulations with respect to the punching shear design provisions. Such empirical equations are typically calibrated on the basis of laboratory tests performed on simplified geometries (usually isolated specimens) with usually statically-determined loading conditions. On the contrary, actual structures, particularly two-way slabs, are continuous and highly ...
متن کاملUltimate Unbonded Tendon Stress in CFRP Strengthened Post-Tensioned Indeterminate I-Beams Cast with HSCs
Based on the bending experiment for two-span continuous post-tension beams with unbounded tendons and externally applied CFRP sheets, the analysis of the stress increment of unbonded tendons is monitored in the loading process. Since self-compacting concrete (SCC) is a suitable innovation,, understanding the implementation of this type of concrete on the ultimate unbonded tendon stress is criti...
متن کاملUltimate Tendon Stress in CFRP Strengthened Unbounded HSC Post-Tensioned Continuous I-Beams
The use of unbounded tendons is common in prestressed concrete structures and evaluation of the stress increase in unbonded tendons at ultimate flexural strength of such structure has posed a great challenge over the years. Based on the bending experiment for two-span continuous post-tension beams with unbounded tendons and externally applied CFRP sheets, the monitoring of the stress increment ...
متن کاملStrengthening of Existing RC Two-Way Slabs using New Combined FRP fabric/rod Technique
This study presents the results of an experimental program to investigate the effectiveness of an innovative combined FRP technique using combination of externally bonded (EB) FRP fabrics and near surface mounted (NSM) FRP rods for flexural strengthening of existing reinforced concrete (RC) two-wayslabs with low clear cover thickness. Three full-scale RC slabs (1500×1500×120 mm) were tested und...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Korean Society of Hazard Mitigation
سال: 2011
ISSN: 1738-2424
DOI: 10.9798/kosham.2011.11.6.053