Beehive (Hexagrid), New Innovated Structural System for Tall Buildings

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Seismic Performance of Combined Horizontal and Vertical Hexagrid Structural System for High-rise Buildings

Summary In this study, the seismic performance of hexagrid structures which are composed of horizontal and vertical hexagrid by using a transitional story, has been investigated. To this end, 10 models of 50-story hexagrid structures were designed. 9 models with horizontal hexagrid cells which transited to vertical cells using a transitional story, and a model of completely horizontal hexagrid ...

متن کامل

OPTIMUM DESIGN OF TMD SYSTEM FOR TALL BUILDINGS

High tall buildings are more susceptible to dynamic excitations such as wind and seismic excitations. In this paper, design procedure and some current applications of tuned mass damper (TMD) were studied. TMD was proposed to study response of 20 storey height building to seismic excitations using time history analysis with and without the TMD. The study indicates that the response of structur...

متن کامل

A Comparative Study on Seismic Performance of Hexagrid, Diagrid and Tubular Structural Systems

Hexagrid structural system is an innovated system with structural behavior which is similar to a tubular system. In this paper, a numerical study is conducted to estimate the seismic performance of horizontal hexagrid concerning the combined horizontal and vertical hexagrid, tubular and diagrid structural systems. First 30 and 50 story buildings are modeled using ETABS, then pushover and nonlin...

متن کامل

A Study on Static and Dynamic Behavior of Outrigger Structural System for Tall Buildings

ISSN 2277-5056 | © 2012 Bonfring Abstract--In the present paper an investigation has been performed to examine the behavior of various alternative 3D models using ETABS software for reinforced concrete structure with central core wall with outrigger and without outrigger by varying the relative flexural rigidity from 0.25 to 2.0 with step of 0.25. Also the position of outrigger has been varied ...

متن کامل

Structural design of tall buildings knowledge acquisition study report

A knowledge acquisition study in the domain of tall building design was conducted. Domain experts, five structural engineers and one architect, were interviewed. The experts were asked a set of questions divided into design process and design content questions, and asked to simulate a design scenario. The experts were also shown, and asked to critique, a prototype implementation of a design gra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of High-Rise Buildings

سال: 2016

ISSN: 2234-7224

DOI: 10.21022/ijhrb.2016.5.4.251