Beam Position Monitor Characterization for the High Energy Photon Source Synchrotron

نویسندگان

چکیده

Beam position monitor (BPM) characterization has been widely studied at the synchrotron. The characteristic impedance of a stripline BPM was designed using simulation and measured time-domain reflectometer method. mechanical electrical parameters feedthroughs with buttons used for BPMs were measured. Special care taken in analysis consistency four channels BPM. sorted based on their capacitance values. This paper presents results BPMs. electro-mechanical offsets Lambertson method, calibration coefficients stretched wire. differences introduced during mass production determined by statistical measurement results.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A phase-space beam position monitor for synchrotron radiation

The stability of the photon beam position on synchrotron beamlines is critical for most if not all synchrotron radiation experiments. The position of the beam at the experiment or optical element location is set by the position and angle of the electron beam source as it traverses the magnetic field of the bend-magnet or insertion device. Thus an ideal photon beam monitor would be able to simul...

متن کامل

A Single-pass Beam Position Monitor for the Injection Beam at the Photon Factory Storage Ring

A single-pass beam-position monitor (BPM) system to measure the injection-beam positions in the storage ring was developed. Bipolar bunch signals extracted through button electrodes were recorded in real time using a high-speed waveform digitizer, and the beam positions were determined from the amplitudes of the bipolar signals. The beam positions at 8 BPMs were measured at the same time by mea...

متن کامل

A Versatile High Resolution Beam Position Monitor*

A new kind of Cerenkov beam position monitor is described. The counter, though relatively simple and inexpensive, has high sensitivity, introduces a minimal amount of multiple scattering, and is capable of high spatial resolution over a wide range of beam currents 0 Measurements of the position of the SLAC electron beam to an accuracy of I l/2 mm have been made for electron currents from 20 nA ...

متن کامل

Advanced Photon Source Monopulse rf Beam Position Monitor Front-End Upgrade*

This paper will describe and analyze the rf beam position monitor (RFBPM) frontend upgrade for the Advanced Photon Source (APS) storage ring. This system is based on amplitude-to-phase (AM/PM) conversion monopulse receivers. The design and performance of the existing BPM front-end will be considered as the base-line design for the continuous effort to improve and upgrade the APS beam diagnostic...

متن کامل

Beam Position Monitor Development for the Usr*

Capacitive pick-ups for closed-orbit measurements are presently under development for an Ultra-low energy Storage Ring (USR) at the future Facility for Low-energy Antiproton and Ion Research (FLAIR). Low-intensity, low-energy antiprotons impose challenging demands on the sensitivity of the monitoring system. The nondestructive beam position monitors (BPMs) should be able to measure about 10 par...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Symmetry

سال: 2023

ISSN: ['0865-4824', '2226-1877']

DOI: https://doi.org/10.3390/sym15030660