Beam loss background and collimator design in CEPC double ring
نویسندگان
چکیده
منابع مشابه
Design and clinical utility of a fan beam collimator for SPECT imaging of the head.
A long bore fan beam collimator for imaging the head was designed and constructed for a SPECT system with a rotating scintillation camera. In order to avoid the patient's shoulder during rotation of the camera with a thick camera housing, the long bore design is necessary to allow the collimator to get close to the patient's head for improved spatial resolution. Operating at the minimum radius ...
متن کاملBeam characteristic of P.E collimators Add-on multileaf collimator
Introduction: Multileaf collimators (MLCs) are computer-controlled devices which are Useful and cost-effective tools for conformal therapy and intensity modulation radiotherapy (IMRT). Nowadays MLCs are important and standard configuration of the new medical linear accelerators which are substitute of conventional Blocks and has eliminated the ...
متن کاملSecondary Electron Production at the SNS Storage Ring Collimator*
S.Y. Zhang Brookhaven National Laboratory, Upton, lWZ USA CWJ-j perpendicular rncident hasanangle8= O,and a range of Secondary electron (SE) production is briefly reviewed. If the collimator of the SNS storage ring allows proton beam scraping to take place, the electron yield might be quite large. At the AGS Booster, by steering the AU3’+ ion beam into the electrostatic rnflector,beam scraping ...
متن کامل“Crystal Collimator” Measurement of CESR particle-beam Source Size
We have measured electron and positron beam source size at CHESS when the Cornell Electron Storage Ring (CESR) is run dedicated for the production of synchrotron radiation. Horizontal source size at several beamlines is expected to shrink by a factor of two but synchrotron (visible) light measurements only provide the vertical size. Therefore a “crystal collimator” using two Bragg reflection in...
متن کاملSPECT using a specially designed cone beam collimator.
A specially designed high resolution converging collimator having a focal length of 50 cm has been evaluated for cone beam single photon emission computed tomography (SPECT). The focal region was investigated by imaging a point source placed at the expected focal point and along the central ray of the collimator in front of and behind the focal point. Technetium-99m point source sensitivities m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2018
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/1067/2/022010