Bayesian Restoration Using a New Nonstationary Edge-Preserving Image Prior
نویسندگان
چکیده
منابع مشابه
1 Bayesian Restoration Using a New Hierarchical Directional Continuous Edge Image Prior
In this paper we propose a class of image restoration algorithms based on the Bayesian approach and a new hierarchical spatially adaptive image prior. The proposed prior has two desirable features. First, it models the image discontinuities in different directions with a continuous value model. Thus, it generalizes the on/off (binary) line process idea used in previous image priors within the c...
متن کاملWavelet Domain Image Restoration Using Edge Preserving
In this paper we consider a wavelet-based edge preserving regularization scheme for use in linear image restoration problems. Our efforts build on a collection of mathematical results indicating that wavelets are especially useful for representing functions that contain discontinuities (i.e. edges in two dimensions or jumps in 1D). We interpret the resulting theory in a statistical signal proce...
متن کاملEdge-preserving Regularization in Image Restoration
The reconstruction of an image u(x, y) that describes a real scene from experimental data (observed image) I(x, y) can be identified as an inverse problem. This problem is generally ill-posed in the sense of Hadamard. The regularization of an inverse problem in image processing requires smoothing homogeneous areas of the object without degrading edges. The location of these edges are unknown an...
متن کاملEdge Preserving Model-Based Image Restoration
This paper presents a derivation of a fast recursive filter for image restoration if degradation obeys a linear degradation model with the unknown possibly nonhomogeneous point-spread function. Pixels in the vicinity of steep discontinuities are left unrestored to minimize restoration blurring effect. The degraded image is assumed to follow a causal simultaneous regressive model and the point-s...
متن کاملIterative image reconstruction for CBCT using edge-preserving prior.
On-board cone-beam computed tomography (CBCT) is a new imaging technique for radiation therapy guidance, which provides volumetric information of a patient at treatment position. CBCT improves the setup accuracy and may be used for dose reconstruction. However, there is great concern that the repeated use of CBCT during a treatment course delivers too much of an extra dose to the patient. To re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Image Processing
سال: 2006
ISSN: 1057-7149
DOI: 10.1109/tip.2006.877520