Bayesian characterization of uncertainty in intra-subject non-rigid registration
نویسندگان
چکیده
منابع مشابه
Bayesian characterization of uncertainty in intra-subject non-rigid registration
In settings where high-level inferences are made based on registered image data, the registration uncertainty can contain important information. In this article, we propose a Bayesian non-rigid registration framework where conventional dissimilarity and regularization energies can be included in the likelihood and the prior distribution on deformations respectively through the use of Boltzmann'...
متن کاملHybrid rigid and non-rigid registration algorithm for alignment of intra-subject thoracic and abdominal images
A hybrid rigid and non-rigid registration algorithm has been presented to register thoracic and abdominal CT images of the same subject scanned at different times. The bony structures are first segmented from two different time CT images, respectively. Then, the segmented bony structures in the two respective images are registered based on their boundary points using a soft correspondence match...
متن کاملBayesian Multimodality Non-rigid Image Registration via Conditional Density Estimation
We present a Bayesian multimodality non-rigid image registration method. Since the likelihood is unknown in the general multimodality setting, we use a density estimator as a drop in replacement to the true likelihood. The prior is a standard small deformation penalty on the displacement field. Since mutual information-based methods are in widespread use for multimodality registration, we attem...
متن کاملNon-Rigid Image Registration
An important hypothesis of the research reported in this paper is that dynamic space warping (DSW), a dynamic programming (DP) technique (Bellman 1965, Brown 1996), can be effectively used for object matching and for inference of the image registration warping function. For this end, a novel, robust, and efficient method for non-rigid image registration using DSW in the “length–code” domain is ...
متن کاملCompensation of brain shift during surgery using non-rigid registration of MR and ultrasound images
Background: Surgery and accurate removal of the brain tumor in the operating room and after opening the scalp is one of the major challenges for neurosurgeons due to the removal of skull pressure and displacement and deformation of the brain tissue. This displacement of the brain changes the location of the tumor relative to the MR image taken preoperatively. Methods: This study, which is done...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Image Analysis
سال: 2013
ISSN: 1361-8415
DOI: 10.1016/j.media.2013.03.002