Battery-Powered Portable Rotary Real-Time Fluorescent qPCR with Low Energy Consumption, Low Cost, and High Throughput
نویسندگان
چکیده
منابع مشابه
Portable, Battery-Operated, Low-Cost, Bright Field and Fluorescence Microscope
This study describes the design and evaluation of a portable bright-field and fluorescence microscope that can be manufactured for $240 USD. The microscope uses a battery-operated LED-based flashlight as the light source and achieves a resolution of 0.8 microm at 1000x magnification in fluorescence mode. We tested the diagnostic capability of this new instrument to identify infections caused by...
متن کاملData Acquisition System for Volcano Monitoring With Real-Time Transmission, Low Cost and Low Power Consumption
An acquisition system has been developed as an evolution of the gDT316 and gCNT16 dataloggers [1]. This new datalogger, gDT524, has several advantages in comparison with the previous versions. The main features, beside the low power consumption and low cost, are: an A/D converter with 24 bits fivechannels inputs, two 16 bits counters, meteorological sensors, real time clock with synchronization...
متن کاملNanofabrication at high throughput and low cost.
The task of nanofabrication can, in principle, be divided into two separate tracks: generation and replication of the patterned features. These two tracks are different in terms of characteristics, requirements, and aspects of emphasis. In general, generation of patterns is commonly achieved in a serial fashion using techniques that are typically slow, making this process only practical for mak...
متن کاملA Hand-Powered, Portable, Low-Cost Centrifuge for Diagnosing Anemia in Low-Resource Settings
This report describes the development of a hand-powered centrifuge to determine hematocrit values in low-resource settings. A hand-powered centrifuge was constructed by using a salad spinner. Hematocrit values were measured by using the hand-powered device, and results were compared with those of a benchtop centrifuge. The packed cell volume (PCV) measured with the hand-powered device correlate...
متن کاملLow-cost microbioreactor for high-throughput bioprocessing.
The design of a microbioreactor is described. An optical sensing system was used for continuous measurements of pH, dissolved oxygen, and optical density in a 2 mL working volume. The K(L)a of the microbioreactor was evaluated under different conditions. An Escherichia coli fermentation in both the microbioreactor and a standard 1 L bioreactor showed similar pH, dissolved oxygen, and optical de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biosensors
سال: 2020
ISSN: 2079-6374
DOI: 10.3390/bios10050049