Basic studies of 3-inch PMT for multi-PMT development
نویسندگان
چکیده
منابع مشابه
Cross-talk suppressed multi-anode MCP-PMT
We have developed a 4-channel multi-anode MCP-PMT, SL10, which exhibits a performance of σTTS ≃ 30 ps for single photons with G ∼ 10 6 and QE = 20% under a magnetic field of B ≤ 1.5T . The cross-talk among anodes has been extensively studied. We have taken two measures to suppress it: one is to configure the SL10 to an effectively independent 4 small pieces of MCP-PMT’s by segmenting an electro...
متن کاملIceCube PMT HV Base Development Status
B. The “New Iseg Base” employs essentially the same HV circuitry as the Old Iseg Base, however, it is distinct from the old version in that it implements a splitground configuration using an isolation amplifier, whereby two DC-isolated grounds are created: the “noisy section” consisting of the digital interface and the oscillator for HV generation and the “analog” section consisting of the cath...
متن کاملLifetime of MCP–PMT
To examine the lifetime of a micro-channel plate photo-multiplier tube, we measured its basic performance, gain, quantum efficiency (QE), transit time spread and dark counts as a function of the integrated amount of irradiated photons up to 2:8 10 photons=cm, corresponding to a 14-year time duration under supposed super-KEKB experimental conditions. The effect of the ion-feedback protection lay...
متن کاملMCP-PMT timing property for single photons
We have measured the performance, especially the timing properties, of micro-channel plate photo-multiplier tubes (MCP-PMTs) by irradiating with single photons with/without a magnetic field. A time resolution of s 1⁄4 30–35 ps was obtained for single photons under 1:5 T: With an MCP-PMT, a small time-of-flight counter, by means of Cherenkov light radiation instead of scintillation light has bee...
متن کاملLifetime-extended MCP-PMT
In order to develop a long-lifetime MCP-PMT under high rates of circumstance, we investigated the degradation of the quantum efficiency (QE) of PMT’s with a multialkali photocathode. We found that not only positive ions, but also neutral residual gases would damage the photocathode resulting in an enhancement of the work function; their countermeasures were established in newly manufactured squ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2020
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/1468/1/012162