Basic Investigation of a Cerebral Blood Flow Quantification Method without Blood Sampling Method (Improved Brain Uptake Ratio (IBUR)) Using a Fan-beam Collimator

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Usefulness of an Automatic Quantitative Method for Measuring Regional Cerebral Blood Flow Using 99mTc Ethyl Cysteinate Dimer Brain Uptake Ratio

 Objective(s): Improved brain uptake ratio (IBUR), employing 99mTc-ethyl cysteinate dimer (99mTc-ECD), is an automatic non-invasive method for quantitatively measuring regional cerebral blood flow (rCBF). This method was developed by the reconstruction of the theory and linear regression equation, based on rCBF measurement by H215O positron emission tomography. Clarification of differences in r...

متن کامل

[Measurements of cerebral blood flow by the noninvasive microsphere method with 123I-IMP and fan beam collimator: comparison with the continuous arterial blood sampling method].

PURPOSE AND METHODS The noninvasive microsphere (NIMS) method quantifies cerebral blood flow with N-isopropyl-p-[123I]-iodoamphetamine (123I-IMP) without blood sampling of a patient, but when a fan beam collimator is used for collecting raw data in single photon emission computed tomography (SPECT), the procedure is complicated because we have to change the collimator. In phantom and clinical s...

متن کامل

Usefulness of an Automatic Quantitative Method for Measuring Regional Cerebral Blood Flow Using 99mTc Ethyl Cysteinate Dimer Brain Uptake Ratio

OBJECTIVES Improved brain uptake ratio (IBUR), employing (99m)Tc-ethyl cysteinate dimer ((99m)Tc-ECD), is an automatic non-invasive method for quantitatively measuring regional cerebral blood flow (rCBF). This method was developed by the reconstruction of the theory and linear regression equation, based on rCBF measurement by H2 (15)O positron emission tomography. Clarification of differences i...

متن کامل

Improved Method for Noninvasive Measurement of Regional Cerebral Blood Flow

A clinical method for noninvasive measurement of regional cerebral blood flow (rCBF) and blood volume (rCBV) is described, based on Obrist's 10 minute, desaturation method after 1 minute inhalation of Xe. Sixteen collimated probes are placed over both hemispheres and brain stem-cerebellar regions. End-tidal Xe curves are used for correction of recirculation. KEV discriminators are set to record...

متن کامل

A Nonlinear Variational Method for Improved Quantification of Myocardial Blood Flow Using Dynamic H2O PET

H2O as a PET-tracer offers the opportunity to examine perfusion of blood into tissue non-invasively (cf. [1]). It features a short radioactive half-life (≈ 2 min.) and therefore adds a smaller radiation exposure to the patient in comparison to other tracers. The disadvantages arising from the short radioactive half-life are noisy, low-resolution reconstructions. Previous algorithms first recons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Radiological Technology

سال: 2018

ISSN: 0369-4305,1881-4883

DOI: 10.6009/jjrt.2018_jsrt_74.11.1302