Basic characterization of uranium by high-resolution gamma spectroscopy
نویسندگان
چکیده
منابع مشابه
Basic characterization of highly enriched uranium by gamma spectrometry
Gamma-spectrometric methods suitable for the characterization of highly enriched uranium samples encountered in illicit trafficking of nuclear materials are presented. In particular, procedures for determining the U, U, U, U and U contents and the age of highly enriched uranium are described. Consequently, the total uranium content and isotopic composition can be calculated. For determining the...
متن کاملHigh-Resolution Gamma-Ray Spectroscopy
• GEM10P4/CFG-PV4/DWR-30 Coaxial Detector System (Includes detector, cryostat, dewar, preamplifier, and 12-ft. cable pack); typical specifications: 10% relative efficiency, 1.75 keV resolution at 1.332 MeV, 41:1 peak-to-Compton ratio. • 659 0–5 keV Detector Bias Supply • 672 Spectroscopy Amplifier • 480 Pulser • C-24-12 Cables (2 ea.) • C-24-1 Cable • C-29 BNC Tee Connector • 4001A/4002D NIM Bi...
متن کاملLow-resolution gamma-ray measurements of uranium enrichment.
We have developed smaller, lighter hardware (MCA and shielded detectors) that has been successfully transferred to the commercial sector. We have developed software that has received limited testing, the next release should be sufficiently robust for wide release to the general public. We have had initial success with more sophisticated analysis methods. We are pursuing medium-resolution tors a...
متن کاملHigh-resolution solution structure of basic fibroblast growth factor determined by multidimensional heteronuclear magnetic resonance spectroscopy.
The high-resolution solution structure of recombinant human basic fibroblast growth factor (FGF-2), a protein of 17.2 kDa that exhibits a variety of functions related to cell growth and differentiation, has been determined using three-dimensional heteronuclear NMR spectroscopy. A total of 30 structures were calculated by means of hybrid distance geometry--simulated annealing using a total of 28...
متن کاملHIGH RESOLUTION LASER SPECTROSCOPY IN COLD SUPERSONIC MOLECULAR BEAMS COOLING, REDUCTION OF DOPPLER WIDTH AND APPLICATION
The cooling of molecules during the adiabatic expansion of supersonic seeded molecular beams is reviewed and illustrated by the example of NO -molecules. The reduction of the Doppler width by collimation of the beam and the cooling to low rotational temperatures brings a significant simplification of the complex NO -absorption spectrum and allows its assignment. The measured rotational tem...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Engineering and Technology
سال: 2018
ISSN: 1738-5733
DOI: 10.1016/j.net.2018.04.008