Baseline Noise and Measurement Uncertainty in Liquid Chromatography
نویسندگان
چکیده
منابع مشابه
Baseline Noise in High-Performance Liquid Chromatography with Electrochemical Detection
The chromatographic baseline was converted to power spectrum by Fourier transform to show the frequency dependence of noise. The spectral analysis of chromatographic baseline was made under various experimental conditions for high-performance liquid chromatography with electrochemical detection (HPLC-ECD). From the spectral analysis, it was found easily that a system using a small stroke pump a...
متن کاملREACHABILITY UNDER UNCERTAINTY and MEASUREMENT NOISE
This report deals with the problem of reachability under unknown but bounded disturbances and piecewise open-loop controls which may be feedback-corrected at isolated “points of correction”. It is presumed that there are hard bounds on the controls and the unknown but bounded items. The open-loop controls are reassigned at prespecified points of correction on the basis of additional information...
متن کاملSources of uncertainty in gas chromatography and high-performance liquid chromatography
Analysts are increasingly being required to evaluate the uncertainty associated with their methods. Indeed, estimating the uncertainty of an analytical result is an essential part of quantitative analysis. The approach of the International Organisation for Standardisation to uncertainty estimation requires the identification of the possible sources of uncertainty for a procedure, followed by th...
متن کاملMeasurement of Strontium-90 in the Persian Gulf Fish by Extraction Chromatography with Sr-resin and Liquid Scintillation Counter
Background: Despite its beneficial effects on human life, the nuclear industry has its own risks. Strontium 90 (90Sr) is one of the most dangerous radionuclides produced by the uranium 235 fission, and replaces the bone calcium in the human body, which causes cancer. Ensuring the safety of nuclear facilities to protect employees, people and the environment is among the main goals of nuclear saf...
متن کاملSerum lipoprotein measurement--liquid chromatography and sequential floatation (ultracentrifugation) compared.
An HPLC method [J. Biochem. (Tokyo) 91:1381, 1982] was used for evaluating serum lipoproteins, with on-line monitoring of either cholesterol or phospholipids. Five well-distinguished lipoprotein fractions were observed, based on their particle sizes. Serum of 15 normal persons, 12 subjects with various types of hyperlipidemia, 20 patients with various liver diseases, and two cases of familial L...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 2007
ISSN: 0910-6340,1348-2246