Balloon-trapped Technique for Successful OptEase Filter Retrieval
نویسندگان
چکیده
منابع مشابه
Atherotome dislodgement and successful retrieval during cutting balloon pulmonary angioplasty.
Cutting balloons (CBs) are beneficial for dilation of resistant branch pulmonary artery (PA) stenosis in children.1 There are rare reports of atherotome fracture2 and a Food and Drug Administration adverse event report of a fractured atherotome dislodging and remaining in the patient.3 We report CB atherotome dislodgement and embolization with successful retrieval in a patient with Alagille syn...
متن کاملpercutaneous retrieval of an embolized catheter tip with the balloon dilatation technique
conclusions the present case appears to offer a safe and relatively simple method of balloon dilatation inside the lumen of the embolized fragment when the foreign body is too distal to retrieve with conventional snare systems. introduction increasing numbers of complex percutaneous coronary interventions have been accompanied by various intra-procedural complications. the fracture and emboliza...
متن کاملSuccessful cases of difficult inferior vena cava filter retrieval with the use of biopsy forceps: Biopsy forceps technique
OBJECTIVES For treatment and prevention of deep vein thrombosis(DVT) and pulmonary embolism(PE), retrievable inferior vena cava(IVC) filters have commonly been used as an effective bridge to anticoagulation. However, we experienced unexpected difficulty in endovascular retrieval of some IVC filters. Most problems were due to endovascular treatment devices issues, filter intimal migration, filte...
متن کاملPathological Significance of Tissue Trapped in Retrieved OptEase Vena Cava Filter at 18th Day after Installation in Patient with Deep Vein Thrombosis
The retrievable type of inferior vena cava filter has been widely used to prevent pulmonary thromboembolism in patients with deep vein thrombosis and contraindication of anticoagulation. Physicians make considerable efforts to remove the filter according to the manufacturer and US Food and Drug Administration safety advisory recommendation. However, forced filter retrieval might cause vascular ...
متن کاملSuccessful Use of Biliary Duct Balloon Dilator in Repairing Post-Surgical Esophageal Stricture in premature infant
Congenital esophageal atresia needs to be surgically corrected as soon as possible. Some will present with post surgical stricture that needs to be dilated by a balloon dilator. This procedure is difficult in premature born due to infant esophageal size and availability of equipments. We herby report the first case in a premature infant with post surgical esophageal stricture of esophageal atre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of Vascular Diseases
سال: 2011
ISSN: 1881-641X,1881-6428
DOI: 10.3400/avd.cr.10.01041