Balloon dilatation of the aortic valve after previous surgical valvotomy: immediate and follow up results.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate and Short-term Follow-Up of Aortic Coarctation Balloon Angioplasty and Stenting

Background Aortic Coarcatation (CoA) is one of the congenital heart diseases with the rate of 5-8% of Coronary heart diseases(CHDs). Balloon angioplasty is now one of the effective way of treatment for CoA, native or Re-coarctation (Re-CoA). We aimed to assess the immediate, and short term response to angioplasty and stenting, and also complications. Materials and Methods Balloon angioplasty wi...

متن کامل

Results of three to 10 year follow up of balloon dilatation of the pulmonary valve.

BACKGROUND The results of immediate and short term follow up of balloon dilatation of the pulmonary valve have been well documented, but there is limited information on long term follow up. OBJECTIVE To evaluate the results of three to 10 year follow up of balloon dilatation of the pulmonary valve in children and adolescents. SETTING Tertiary care centre/university hospital. DESIGN Retros...

متن کامل

Late clinical and echocardiographic follow up after percutaneous balloon dilatation of the mitral valve.

OBJECTIVE To assess the outcome after attempted percutaneous balloon dilatation of the mitral valve in patients with severe mitral stenosis between February 1986 and June 1992. DESIGN Clinical state, mitral valve area, and restenosis at follow up were analysed. Mitral valve area as determined by the Gorlin formula, planimetry, and Doppler methods was compared before and after dilatation and a...

متن کامل

Aortic valve reinterventions after balloon aortic valvuloplasty for congenital aortic stenosis intermediate and late follow-up.

OBJECTIVES the aim of this study was to evaluate the long-term results of transcatheter balloon aortic valvuloplasty, the preferred treatment for congenital aortic stenosis (AS). BACKGROUND aortic valve function and reintervention late after this procedure are not well characterized. METHODS from 1985 to 2008, 563 patients underwent balloon dilation for congenital AS. After excluding those ...

متن کامل

Balloon dilatation of the aortic valve for inoperable aortic stenosis.

The place of balloon dilatation of the aortic valve in the treatment of calcific aortic stenosis is controversial. Thirty two patients (mean age 76) in whom valve replacement was contraindicated were followed up for three to 24 months (mean 8); 25 were in functional class III or IV according to the New York Heart Association's classification. Major complications of the procedure occurred in fou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Heart

سال: 1994

ISSN: 1355-6037

DOI: 10.1136/hrt.71.6.558