Bad data analysis and detection using PMU with UPQC integration to grid during fault conditions
نویسندگان
چکیده
<span lang="EN-US">Analysis of bad data in an IEEE 14 bus system with <a name="_Hlk121211016"></a>phasor measuring units (PMU) devices is carried out this paper. The normal operating condition achieved from the PMU compared to during faults system. A principal component analysis (PCA) technique proposed paper for distinguishing difference between transmission and fault conditions. PCA approach detects dynamical magnitudes measurements taken also determines noise caused by disturbances. grid updated unified power quality conditioner (UPQC) improvising parameters mitigate fault. use a comparative measured components analyzing performance under different simulation these modules Simulink environment MATLAB software done concerning time.</span>
منابع مشابه
Dynamic Analysis of Grid Connected Wind Turbine with a Permanent Magnet Synchronous Generator during Fault Conditions
The use of wind turbines is increasing at very high rates in many countries around the world. Studies to evaluate the impact of connecting these new generation units to the existing power systems must be done. This paper proposes a wind energy conversion system for a grid connected permanent magnet synchronous generator (PMSG) and power electronic converter system. The model includes a PMSG mod...
متن کاملImpacts of Bad Data on the PMU based Line Outage Detection
Today’s power systems become more prone to cyberattacks due to the high integration of information technologies. In this paper, we demonstrate that the outages of some lines can be masked by injecting false data into a set of measurements. The success of the topology attack can be guaranteed by making that: 1)the injected false data obeys KCL and KVL to avoid being detected by the bad data dete...
متن کاملOnline Inertia Constant and Thévenin Equivalent Estimation Using PMU Data
In this paper a new algorithm based on phasor measurements for estimating the Thévenin Equivalent (TE) and system inertia constant is proposed. The method estimates the network TE seen from a generator terminal and equivalent system inertia constant by means of phasor data that is available at Phasor Data Concentrator (PDC) center. It is shown that the parameters of the TE could be estimated at...
متن کاملGrid Stabilization with PMU Signals- A Survey
This paper presents critical survey along with the novel concept of smart power flow controller with Phasor Measurement Units (PMUs) signals for stability enhancement of a large power system. Also, the current status of Wide Area Measurement Systems (WAMS) and developments in real time applications of synchrophasor technology in power system has been adequately addressed. It has been noticed th...
متن کاملAnalysis of Wind Farm to Weak-Grid Connection Using Fuzzy Based Unified Power Quality Compensator (UPQC)
In this paper a compensation strategy based on a particular CUPS device, the Unified Power Quality Compensator (UPQC) has been proposed. A customized internal control scheme of the UPQC device was developed to regulate the voltage in the WF terminals, and to mitigate voltage fluctuations at grid side. The voltage regulation at WF terminal is conducted using the UPQC series converter, by voltage...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Power Electronics and Drive Systems
سال: 2023
ISSN: ['2722-2578', '2722-256X']
DOI: https://doi.org/10.11591/ijpeds.v14.i1.pp256-265