Backflow Power Optimization of DAB Based on Asymmetric Duty Cycle and Internal Phase Shift Control
نویسندگان
چکیده
Dual active bridge (DAB) converter with single-phase-shifting (SPS) control would produce large backflow power when voltage regulation ratio deviates from 1 or under light load, an asymmetric duty cycle and internal phase shift (ADIPS) was proposed which controls the transmission by phase-shift can be eliminated load therefore improves efficiency of DAB converter. By establishing mathematical models inductor current power, working principle method given as well cause analyzed. The constraints zero optimization ADIPS presented. At last, experimental prototype is used to obtain validation results, simulation results verify excellent performance strategy in eliminating load.
منابع مشابه
application of upfc based on svpwm for power quality improvement
در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...
15 صفحه اولBackflow Power Optimization Control for Dual Active Bridge DC-DC Converters
Abstract: This paper proposes optimized control methods for global minimum backflow power based on a triple-phase-shift (TPS) control strategy. Three global optimized methods are derived to minimize the backflow power on the primary side, on the secondary side and on both sides, respectively. Backflow power transmission is just a portion of non-active power transmission in a dual active bridge ...
متن کاملDesign and optimization of an energy hub based on combined cycle power plant to improve economic and exergy objectives
This paper uses the energy hub concept to meet the water, heat and electricity demand of a power plant in the Qeshm island in south of Iran. Given the power plant’s high potential for waste heat recovery and some scenarios were considered using the hub energy concept based on energy, exergy, environmental and economic analyzes in terms of meeting the demands of the hub and purchasing/selling en...
متن کاملReduction of Voltage Stress in the Full Bridge BIBRED by Duty Ratio and Phase Shift Control
A new control scheme is presented which provides simultaneous control of the output voltage and the energy storage capacitor voltage in the full-bridge Boost Integrated with Buck RectifiedEnergy storage/Dc-dc converter (full-bridge BIBRED). The new control scheme solves the problem of wide voltage excursions for the energy storage capacitor voltage under variable load conditions. A low frequenc...
متن کاملQueue-Based Adaptive Duty Cycle Control for Wireless Sensor Networks
This paper proposes a control-based approach to duty cycle adaptation for wireless sensor networks. The proposed method controls duty cycle through queue management in order to achieve high performance under variable traffic rates. To have energy efficiency while minimizing the delay, we design a feedback controller, which adapts sleeping interval time to traffic change dynamically by constrain...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Access
سال: 2023
ISSN: ['2169-3536']
DOI: https://doi.org/10.1109/access.2023.3257057