B-scan-sectioned dynamic micro-optical coherence tomography for bulk-motion suppression
نویسندگان
چکیده
In this Letter, we present B-scan-sectioned dynamic micro-optical coherence tomography (BD-MOCT) for high-quality sub-cellular contrast imaging. Dynamic (D-MOCT) is a functional optical (OCT) technique performed on high-resolution (micron level) OCT systems; hundreds of consecutive B-scans need to be acquired signal extraction, which requires relatively long data acquisition time. Bulk motions occurring during (even at the micron may degrade quality obtained images. BD-MOCT, each full B-scan divided into several sub-B-scans, and sub-B-scan repeats multiple times before sample beam moves next sub-B-scan. After all sub-B-scans are completely acquired, stitch same number B-scans. way, time interval between two stitched could reduced bulk-motion suppression. The scanning protocol modulates sequences fast repeat improving image quality, while total remains almost same.
منابع مشابه
Motion artifact suppression in full-field optical coherence tomography.
Significant motion artifacts limit the performance of conventional full-field optical coherence tomography (FF-OCT) for in-vivo imaging. We present a theoretical and experimental study of those limitations. A new FF-OCT system suppressing most of artifacts due to sample motions is demonstrated using instantaneous phase shifting with nonpolarizing optics and pulsed illumination. The experimental...
متن کاملConical scan polarization-sensitive optical coherence tomography.
We report on a new articular cartilage imaging technique with potential for clinical arthroscopic use, by supplementing the variable-incidence-angle polarization-sensitive optical coherence tomography method previously developed by us with a conical beam scan protocol. The technique is validated on bovine tendon by comparing experimental data with simulated data generated using the extended Jon...
متن کاملReal-time bulk-motion-correction free Doppler variance optical coherence tomography for choroidal capillary vasculature imaging
In this paper, we analyze the retinal and choroidal blood vasculature in the posterior segment of the human eye with optimized color Doppler and Doppler variance optical coherence tomography. Depth-resolved structure, color Doppler and Doppler variance images are compared. Blood vessels down to the capillary level were detected and visualized with the optimized optical coherence color Doppler a...
متن کاملDynamic Optical Coherence Tomography in Dermatology.
Optical coherence tomography (OCT) represents a non-invasive imaging technology, which may be applied to the diagnosis of non-melanoma skin cancer and which has recently been shown to improve the diagnostic accuracy of basal cell carcinoma. Technical developments of OCT continue to expand the applicability of OCT for different neoplastic and inflammatory skin diseases. Of these, dynamic OCT (D-...
متن کاملEnhanced optical coherence tomography imaging by multiple scan averaging.
AIMS To describe a method for computerised alignment and averaging of sequences in optical coherence tomography (OCT) B-scans and to present selected clinical observations based on the resulting improvement in retinal imaging. METHODS A methodological study and retrospective investigation of selected cases. Five human subjects were included, one healthy subject, two patients with central sero...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chinese Optics Letters
سال: 2022
ISSN: ['1671-7694']
DOI: https://doi.org/10.3788/col202220.021102