B 1 inhomogeneity correction of RARE MRI with transceive surface radiofrequency probes
نویسندگان
چکیده
منابع مشابه
SOM for intensity inhomogeneity correction in MRI
Given an appropriate imaging resolution, a common Magnetic Resonance Imaging (MRI) model assumes that object under study is composed of piecewise constant materials, so that MRI produces piecewise constant images. The intensity inhomogeneity (IIH) is modeled by a multiplicative inhomogeneity field. It is due to the spatial inhomogeneity in the excitatory Radio Frequency (RF) signal and other ef...
متن کاملA Concentrically Shielded Transceive Array Coil Optimized for B1+ Inhomogeneity Correction at 7T
Introduction: A multiple channel transceive array offers the possibility for flexible mitigation of the transmit inhomogeneity at high fields through either B1 + shimming or by the use of spatially tailored RF excitation pulses accelerated to useful durations using parallel transmit (pTx). Accelerating the transmit RF pulses requires a distinct spatial sensitivity profile. One of the major prob...
متن کاملReview of Intensity Inhomogeneity Correction Methods for Brain Mri Images
Intensity inhomogeneity is a smooth intensity change inside originally homogeneous regions. The intensity inhomogeneity degrades performance of image processing algorithms. Intensity inhomogeneity correction methods are important image processing algorithms which are used to reduce the inhomogeneity. Brain image intensity inhomogeneity correction is one of the most important parts of clinical d...
متن کاملInteraction between noise suppression and inhomogeneity correction in MRI
While cardiovascular disease is the leading cause of death in most developed countries, SPAMM-MRI can reduce morbidity by facilitating patient diagnosis. An image analysis method with a high degree of automation is essential for clinical adoption of SPAMM-MRI. The degree of this automation is dependent on the amount of thermal noise and surface coil-induced intensity inhomogeneity that can be r...
متن کاملConsistent intensity inhomogeneity correction in water-fat MRI.
PURPOSE To quantitatively and qualitatively evaluate the water-signal performance of the consistent intensity inhomogeneity correction (CIIC) method to correct for intensity inhomogeneities METHODS Water-fat volumes were acquired using 1.5 Tesla (T) and 3.0T symmetrically sampled 2-point Dixon three-dimensional MRI. Two datasets: (i) 10 muscle tissue regions of interest (ROIs) from 10 subject...