Axially loaded RC columns repaired on one side with cement-based mortars
نویسندگان
چکیده
منابع مشابه
Time-Dependent Structural Behavior of Repaired Corroded RC Columns Located in a Marine Site
The chloride corrosion of reinforcing steel in reinforced concrete (RC) structures is a significant reason for premature deterioration and failure of RC structures in aggressive environments such as Persian Gulf region. This is one of the most important sources of engineering and economic problems in developed countries. So, the repair and maintenance of RC structures exposed to corrosive envir...
متن کاملDamage Detection of Axially Loaded Beam: A Frequency-Based Method
The present study utilizes an analytical method to formulate the three lowest modal frequencies of axially-loaded notched beam through both crack location and load level in a specific format that can be used in existing frequency-based crack-identification methods. The proposed formula provides a basis to shift into two states, one with axial loading and the other without any loading whatsoever...
متن کاملOPTIMAL PERFORMANCE-BASED SEISMIC DESIGN OF COMPOSITE BUILDING FRAMES WITH RC COLUMNS AND STEEL BEAMS
Composite RCS building frames integrate reinforced concrete columns with structural steel beams to provide an efficient solution for the design and construction of earthquake-resisting structures. In this paper, an optimization framework is developed for performance-based seismic design of planar RCS moment resisting frames. The objective functions are defined as minimizing the construction cos...
متن کاملQuantifying the benefits of lime additions in cement based mortars
The European Lime Association (EuLA) have instigated a project to identify and quantify the benefits associated with the addition of hydrated lime to cement based mortars, and more importantly, filling the gaps that exist in the evidence in respect of the benefits of hydrated lime additions to workability, bond strength development, durability and in addition the modes of failure of mortars whn...
متن کاملFire behavior of axially loaded slender high strength concrete - filled tubular columns
This paper describes sixteen fire tests conducted on slender circular hollow section columns filled with normal and high strength concrete, subjected to concentric axial loads. The test parameters were the nominal strength of concrete (30 and 80 MPa), the infilling type (plain concrete, reinforced concrete and steel fiber reinforced concrete) and the axial load level (20% and 40%). The columns ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Construction and Building Materials
سال: 2018
ISSN: 0950-0618
DOI: 10.1016/j.conbuildmat.2018.05.102