AXIAL LOAD RATIO LIMIT FOR ATTAINMENT OF FULL PLASTIC MOMENT OF CONCRETE FILLED SQUARE STEEL TUBULAR BEAM-COLUMNS

نویسندگان

چکیده

The objective of this study is to propose the axial load ratio which assure that strengths CFT beam-columns attain full plastic moment. subjected constant vertical and monotonic increasing moment are analyzed maximum obtained, taking gradient ratio, value stability index α, materials width-thickness steel tube as analytical parameter. After examining effects parameters on strength, required conditions for attainment consequently summarized Eqs. (12)-(15).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental and Numerical Study on Bar-Reinforced Concrete Filled Steel Tubular Columns Under Axial Compression

The behaviors of bar-reinforced concrete filled steel tubular columns subjected to axial load were studied. One plain concrete filled steel tubular column and three bar-reinforced concrete filled steel tubular columns were tested. The deformation of specimens and the strain of steel tubes were measured. Based on experimental researches, a simple numerical analysis method was presented to simula...

متن کامل

Investigating of the Effect of Concrete Confinement on the Axial Performance of Circular Concrete Filled Double-Skin Steel Tubular (CFDST) Long Columns

In this study, the co-operation of steel and concrete in composite columns is considered. Using numerical modeling to study the behavior of these sections, a new type of sections, namely Concrete Filled Double-Skin steel Tubular (CFDST) columns, is introduced. The parameters and techniques that influence the numerical simulation that bring this modeling closer to...

متن کامل

Cyclic Evolution of Damage and Beam-column Interaction Strength of Concrete-filled Steel Tube Beam-columns

The assessment of response of composite seismic force resisting systems requires accurate nonlinear formulations for the composite members. In this work, reporting the first phase of a NEES project, a three-dimensional distributed plasticity formulation is presented for both circular and rectangular composite concrete-filled steel tubes (CFTs) that includes new constitutive models for the concr...

متن کامل

A unified formulation for circle and polygon concrete-filled steel tube columns under axial compression

Current design practice of concrete-filled steel tube (CFST) columns uses different formulas for different section profiles to predict the axial load bearing capacity. It has always been a challenge and practically important issue for researchers and design engineers who want to find a unified formula that can be used in the design of the columns with various sections, including solid, hollow, ...

متن کامل

Mechanical Behavior of Recycled Aggregate Concrete-Filled Steel Tubular Columns before and after Fire

Recycled aggregate concrete (RAC) is an environmentally friendly building material. This paper investigates the mechanical behavior of recycled aggregate concrete filled steel tube (RACFST) columns exposed to fire. Two groups of 12 columns were designed and tested, under axial compression, before and after fire, to evaluate the degradation of bearing capacity due to fire exposure. Six specimens...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nihon Kenchiku Gakkai ko?zo?-kei ronbunshu?

سال: 2023

ISSN: ['1881-8153', '1340-4202']

DOI: https://doi.org/10.3130/aijs.88.1027