Designing Axial Flow Fan for Flow and Noise
A comprehensive finite element methodology is developed to predict the compressible flow performance of a non-symmetric 7-blade axial flow fan, and to quantify the source strength and sound pressure levels at any location in the system. The acoustic and flow performances of the fan are predicted simultaneously using a computational aero-acoustic technique combining transient flow analysis and n...
متن کاملMulti-channel Active Control of Axial Cooling Fan Noise
A multi-channel active control system has been applied to the reduction of free-field tonal noise from a small axial cooling fan, typical of those used in office equipment and other technology. The experimental apparatus consists of an aluminum enclosure which houses the fan, an infrared detector-emitter pair which serves as a reference sensor, loudspeakers, microphones, and appropriate filters...
متن کاملFlow Characteristics Impeller Change of an Axial Turbo Fan
In this paper, three dimensional flow characteristic was presented by a revision of an impeller of an axial turbo fan for improving the airflow rate and the static pressure. TO consider an incompressible steady three-dimensional flow, the RANS equations are used as the governing equations, and the standard k-ε turbulence model is chosen. The pitch angles of 44°, 54°, 59°, and 64° are implemente...
متن کاملSession 1pEAa: Active and Passive Control of Fan Noise 1pEAa1. Active control of axial and centrifugal fan noise
Both axial and centrifugal fans are used to cool information technology (IT) equipment. These fans generate noise that can be annoying to their users, particularly the tonal noise that can be radiated. Work has focused on developing a method to attenuate the tonal noise associated with both of these types of fans. A compact system is used, whereby control sources are placed in close proximity t...
متن کاملEffect of Blade Design Parameters on Air Flow through an Axial Fan
The objective of this paper is the numerical study of the flow through an axial fan and examining the effects of blade design parameters on the performance of the fan. The axial fan is extensively used for cooling of the electronic devices and servers. Simulation of the three-dimensional incompressible turbulent flow was conducted by numerical solution of the (RANS) equations for a model. The S...