AXIAL FAN BEARING SYSTEM VIBRATION ANALYSIS

نویسندگان

چکیده

Rotating fan shaft system was investigated experimentally and theoretically to study its dynamic performance. The type of oil used for the bearing taken in consideration during experimental program .Three types were used, SAE 40, 50 degraded oil. During experiments, blades stagger angle changed through angles (20˚, 30˚, 40˚, 50˚). rotational speed also range (0-3000 rpm). All these parameters have two cases (balanced unbalanced fan). performance found by measuring fan, volume flow rate, Reynolds Strouhal numbers, efficiency pressure head. Analytical part represented prepare prediction aerodynamic forces moments each blade predicted obtain rotor future. Experimentally critical obtained x y direction different lubricant viscosities velocities balanced fan. Analysis vibrational response gave important information about rotating system. Acceptable agreement between analytical results.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Vibration Characteristics of PD Control Active Magnetic Bearing and Cracked Rotor System (RESEARCH NOTE)

Crack fault of rotor is one of the most prominent problems faced by magnetic bearing rotor system. In order to improve the safety performance of this kind of machinery, it is necessary to research the vibration characteristics of magnetic bearing cracked rotor system. In this paper, the stiffness model of the crack shaft element was established by the strain energy release rate (SERR) theory. T...

متن کامل

An Overview of Bearing Vibration Analysis

surface stresses, is not the limiting factor and probably accounts for less than 3% of failures in service. Unfortunately though, many bearings fail prematurely in service because of contamination, poor lubrication, temperature extremes, poor fitting/fits, unbalance and misalignment. All these factors lead to an increase in bearing vibration and condition monitoring has been used for many years...

متن کامل

Investigation of Fan Fault Problems Using Vibration and Noise Analysis

Cooling fans are used to solve the thermal problems of most critical electronic parts in systems. Therefore, it is very important to monitor the fans condition periodically dealing with the detection, location and analysis of the possible faults. The fault diagnosis of rotating systems is increasingly paying attention. The main purpose of this study is to investigate the possible faults in a ro...

متن کامل

Flows in Duct for Axial Fan

Axial flow fan has been used for large amount of flow rate in air handling units of industrial application fields. The fan involves a shrouding duct as flow guidance for uniform flows. Pressure difference between before and ahead of rotating blades causes the flows movements. The case where the flow resistance such as a heat exchanger is located prior to the rotors is typical in-field model for...

متن کامل

A Compact Magnetic Bearing System for Axial Flow Blood Pump

In this paper, a compact magnetic bearing system has been developed for axial flow blood pumps. The system is composed of two radial hybrid magnetic bearings (HMBs) and a brushless permanent magnet DC motor. The impeller of the pump is enclosed in the rotor that is suspended by the two HMBs with five-degree of freedom (DOF) control, among which four radial directions are actively controlled, an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Ma?allat? al-handasat?

سال: 2023

ISSN: ['1726-4073', '2520-3339']