Awake tracheal intubation through the intubating laryngeal mask
نویسندگان
چکیده
منابع مشابه
Awake tracheal intubation through the intubating laryngeal mask.
PURPOSE To report successful awake insertion of the intubating laryngeal mask (Fastrach) and subsequent tracheal intubation through it, in a patient with predicted difficult tracheal intubation, due to limited mouth opening, and difficult ventilation through a facemask, due to a large mass at the corner of the mouth. CLINICAL FEATURES A 53-yr-old woman with a large post-gangrenous mass on the...
متن کاملHaemodynamic response to tracheal intubation via intubating laryngeal mask airway versus direct laryngoscopic tracheal intubation.
OBJECTIVE To compare the haemodynamic response to tracheal intubation using either direct larygoscopy or Intubating Laryngeal Mask Airway. METHODS This was a prospective randomized controlled trial. One hundred adult ASA-I and ASA-II patients coming to the Anaesthesia Department of Aga Khan University Hospital were randomly divided into two groups. In group-I endotracheal intubation was done ...
متن کاملBLIND TRACHEAL INTUBATION THROUGH air-Q SUPRALARYNGEAL DEVICE: COMPARISON WITH INTUBATING LARYNGEAL MASK AIRWAY Authors
Background: Supra glotic airway devices are increasingly used in anesthesia and emergency medicine as a rescue for intubation and / or ventilation. This study was designed to investigate the supralaryngeal device air-Q in comparison with the ILMA-Fastrach in order to facilitate a rescue airway and intubation.
متن کاملThe intubating laryngeal mask airway in failed fibreoptic intubation.
PURPOSE Prediction of difficult tracheal intubation is not always reliable and management with fibreoptic intubation is not always successful. We describe two cases in which blind intubation through the intubating laryngeal mask airway (ILMA FasTrach) succeeded after fibreoptic intubation failed. CLINICAL FEATURES The first patient, a 50 yr old man, was scheduled for elective craniotomy for i...
متن کاملComparison of blind tracheal intubation through the intubating laryngeal mask airway (LMA Fastrach™) and the Air-Q™.
This study assessed two disposable devices, the LMA Fastrach™ and the newly developed supraglottic airway device, the Air-Q™, as a conduit for tracheal intubation in 154 healthy adults undergoing elective surgery. Using a non-inferiority approach, the primary outcome measure was successful tracheal intubation within two blind insertion attempts. Successful blind intubation after two attempts wa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Canadian Journal of Anesthesia/Journal canadien d'anesthésie
سال: 1999
ISSN: 0832-610X,1496-8975
DOI: 10.1007/bf03012555