Usefulness of the Medial Portal during Hip Arthroscopy
The current conventional portals for hip arthroscopic surgery are the anterior, anterolateral, and posterolateral portals. For lesions in the medial anteroinferior or posteroinferior portion of the hip, these portals provide insufficient access to the lesion and consequently lead to incomplete treatment. Thus, in such a situation, a medial portal approach might be helpful. However, operators ha...
متن کاملFluid Extravasation Related to Hip Arthroscopy
Methods: We performed a prospective cohort study of 40 consecutive arthroscopies for femoroacetabular impingement. Patient demographics and procedures performed (ie, acetabuloplasty and its size, femoral osteoplasty, and psoas tenotomy) were recorded. The extravasated volume was estimated by the difference between the infused volume and the intraoperatively collected volume. Within 12 hours aft...
متن کاملDermal burn during hip arthroscopy.
Radiofrequency devices are often used during arthroscopic surgery, most commonly of the shoulder and knee, and increasingly in hip arthroscopy. The most commonly described complication is elevation of joint temperature, leading to capsular shrinkage, chondrolysis, and nerve damage. A less commonly reported complication is that of dermal burns from the heated irrigation fluid. There are several ...
متن کاملIntrathoracic fluid extravasation after hip arthroscopy.
The case of intrathoracic extravasation of irrigation fluid after hip arthroscopy in a 21-year-old woman is presented. In this patient intraperitoneal and retroperitoneal fluid collection developed, as seen in other case reports documenting irrigation fluid extravasation during hip arthroscopy. The patient presented to the emergency department on the first postoperative day complaining of short...
متن کاملAvoiding nerve damage during elbow arthroscopy.
To define the anatomical relationships of the nerves to the common arthroscopy portals at the elbow an arthroscope was introduced into 20 cadaver elbows and the positions of the nerves were then determined by dissection. In all cases the posterior interosseous nerve lay close to the radiohumeral joint and to the anterolateral portal. Pronation of the forearm displaced the nerve away from the ar...