Avoiding Bias in Measurements of Fundamental Constants from High Resolution Quasar Spectra
نویسندگان
چکیده
Recent advances in spectroscopic instrumentation and calibration methods dramatically improve the quality of quasar spectra. Supercomputer calculations show that, at high spectral resolution, procedures used some previous analyses spacetime variations fundamental constants are likely to generate spurious measurements, biased systematically towards a null result. Developments analysis also summarised prescription given for new forthcoming data.
منابع مشابه
High Resolution Spectra of Quasar Aals: 3c 191
We discuss new high-resolution (6.7 km/s) spectra of the associated absorption lines (AALs) in the radio-loud quasar 3C 191. The measured AALs have ionizations ranging from Mg I to N V, and multicomponent profiles that are blueshifted by ∼400 to ∼1400 km/s relative to the quasar’s broad emission lines. Excited-state absorption lines of Si II and C II imply volume densities of ∼300 cm and a nomi...
متن کاملPrecision measurements and fundamental constants.
Recent developments in the techniques for making precision measurements and their use in the determination of the fundamental constants are reviewed. Particularly noteworthy developments are clocks with high stability, the proposed redefinition of the meter in terms of the standard for time, and the increased precision with which electrical standards can be maintained. The relevance of precisio...
متن کاملConstraining fundamental constants of physics with quasar absorption line systems
We summarize the attempts by our group and others to derive constraints on variations of fundamental constants over cosmic time using quasar absorption lines. Most upper limits reside in the range 0.5−1.5×10−5 at the 3σ level over a redshift range of approximately 0.5 − 2.5 for the fine-structure constant, α, the proton-to-electron mass ratio, μ and a combination of the proton gyromagnetic fact...
متن کاملFundamental Constants at High Energy
The progress of Particle Physics is closely linked to the progress in the understanding of the fundamental constants, like the finestructure constant, the mass of the electron or nucleon, or the electroweak mixing angle. The relation between the 18 fundamental constants of the Standard Model and the elementary units used in other fields like quantum optics or solid state physics is far from tri...
متن کاملLimits on variations in fundamental constants from 21-cm and ultraviolet Quasar absorption lines.
Quasar absorption spectra at 21-cm and UV rest wavelengths are used to estimate the time variation of x [triple-bond] alpha(2)g(p)mu, where alpha is the fine structure constant, g(p) the proton g factor, and m(e)/m(p) [triple-bond] mu the electron/proton mass ratio. Over a redshift range 0.24 < or = zeta(abs) < or = 2.04, (Deltax/x)(weighted)(total) = (1.17 +/- 1.01) x 10(-5). A linear fit give...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Universe
سال: 2022
ISSN: ['2218-1997']
DOI: https://doi.org/10.3390/universe8050266