Autonomous capillary microfluidic devices with constant flow rate and temperature-controlled valving
نویسندگان
چکیده
PNIPAm ( N -isopropylacrylamide) grafted PDMS capillary microfluidic device with constant flow rate and temperature-triggered stop valve function.
منابع مشابه
Autonomous microfluidic capillary system.
The transport of minute amounts of liquids using microfluidic systems has opened avenues for higher throughput and parallelization of miniaturized bio/chemical processes combined with a great economy of reagents. In this report, we present a microfluidic capillary system (CS) that autonomously transports aliquots of different liquids in sequence: liquids pipetted into the service port of the CS...
متن کاملGas flow in plant microfluidic networks controlled by capillary valves.
The xylem vessels of trees constitute a model natural microfluidic system. In this work, we have studied the mechanism of air flow in the Populus xylem. The vessel microstructure was characterized by optical microscopy, transmission electronic microscopy (TEM), and atomic force microscopy (AFM) at different length scales. The xylem vessels have length ≈15 cm and diameter ≈20μm. Flow from one ve...
متن کاملMicrofab-less Microfluidic Capillary Electrophoresis Devices.
Compared to conventional bench-top instruments, microfluidic devices possess advantageous characteristics including great portability potential, reduced analysis time (minutes), and relatively inexpensive production, putting them on the forefront of modern analytical chemistry. Fabrication of these devices, however, often involves polymeric materials with less-than-ideal surface properties, spe...
متن کاملTip-multi-breaking in Capillary Microfluidic Devices
We report tip-multi-breaking (TMB) mode of droplet breakup in capillary microfluidic devices. This new mode appears in a region embraced by Cai = 0 and lg(Cai) = -8.371(Ca0) -7.36 with Ca0 varying from 0.35 to 0.63 on the Cai - Ca0 phase diagram, Cai and Ca0 being the capillary numbers of inner and outer fluids, respectively. The mode is featured with a periodic, constant-speed thinning of the ...
متن کاملFlow Focusing in Microfluidic Devices
This paper presents numerical analysis of the hydrodynamic flow focusing in rectangular microchannels. The low Reynolds number pressure driven flow in symmetric system of crossed channels with three inlets and one outlet is investigated. The numerical model is used to elucidate the origin of broadening of the focused flow sheet observed experimentally close to the side walls of the outlet chann...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Soft Matter
سال: 2021
ISSN: ['1744-683X', '1744-6848']
DOI: https://doi.org/10.1039/d1sm00625h