Automation of pH Measurement Using a Flow-Through Type Differential pH Sensor System Based on pH-FET
نویسندگان
چکیده
منابع مشابه
Optical pH Sensor Based on Quinizarin for Alkaline pH Regions
The development of an optical pH sensor based on immobilization of quinizarin (1,4-dihydroxyanthraquinone) on a triacetylcellulose membrane was described. The resulting membrane exhibited fast color change from yellow to violet, while changing the pH in alkaline region. The immobilized quinizarin showed a broader dynamic range from (pH 9.4-11.4) with respect to free form (pH 8.8-10.4). The sens...
متن کاملDesign and fabrication of a rapid conductometric pH sensor based on metal-oxide technology
A micro-fabricated metal-oxide based conductometric pH sensor is designed and fabricated in this manuscript. pH sensors have applications in various areas from farming to food processing, human health monitoring, industrial waste products investigation, etc. Accordingly, there is a relatively high demand for a reliable, rapid and precise pH sensor in the market. Relatively precise pH sensors ha...
متن کاملA quantum dot-based ratiometric pH sensor.
A quantum dot-based ratiometric pH sensor that responds to the pH range 6-8 was developed using FITC (fluorescein isothiocyanate) conjugated CdSe/CdZnS nanocrystals.
متن کاملA Flexible Optical pH Sensor Based on Polysulfone Membranes Coated with pH-Responsive Polyaniline Nanofibers
A new optical pH sensor based on polysulfone (PSU) and polyaniline (PANI) was developed. A transparent and flexible PSU membrane was employed as a support. The electrically conductive and pH-responsive PANI was deposited onto the membrane surface by in situ chemical oxidative polymerization (COP). The absorption spectra of the PANI-coated PSU membranes exhibited sensitivity to pH changes in the...
متن کاملpH Measurement with a fiber-optic tissue-pH monitor and a standard blood-pH meter.
Continuous monitoring of the pH of tissue with a glass electrode was initially introduced by Stamm et al. (1). Its potential value in monitoring the high-risk fetus during labor has been demonstrated in several studies (2-4). However, this technique has not been clinically accepted for routine use in labor, mostly because of problems with the application and sustained proper attachment of the r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Sensors and Micromachines
سال: 2007
ISSN: 1341-8939,1347-5525
DOI: 10.1541/ieejsmas.127.367