A novel XAFS measurement system has been developed in which XAFS measurements can be performed including sample-loading and detector adjustments. With this system, XAFS measurements of up to 80 samples in both transmission and fluorescence modes can be carried out. The adjustment of the optical components has also been automated. It not only saves manpower and measurement time, but also improve...

متن کامل

Improvement in XAFS beamline BL01B1 at SPring-8

Beamline BL01B1 was constructed for conventional XAFS measurements using a bending magnet light source at SPring-8 in 1997 [1]. BL01B1 covers a wide energy range from 3.8 to 113 keV using an adjustable inclined double-crystal monochromator and a double mirror system. Here, we describe a newly developed apparatus and the current status of the BL01B1. A time-efficient QEXAFS method was developed ...

متن کامل

Rapid and sensitive XAFS using a tunable X-ray undulator at BL10XU of SPring-8.

The design and performance of the high-brilliance XAFS facility at BL10XU of SPring-8, aimed at rapid and sensitive measurement of X-ray absorption fine structure (XAFS), is reported. Both undulator gap and double-crystal monochromator have been successfully controlled covering a wide energy range (5-30 keV). A versatile goniometer system, consisting of two independent high-precision goniometer...

متن کامل

SPring-8 beamline control system.

The SPring-8 beamline control system is now taking part in the control of the insertion device (ID), front end, beam transportation channel and all interlock systems of the beamline: it will supply a highly standardized environment of apparatus control for collaborative researchers. In particular, ID operation is very important in a third-generation synchrotron light source facility. It is also...

متن کامل

Stable top-up operation at SPring-8.

Top-up operation allows SPring-8 to provide highly stable X-ray beams with arbitrary filling patterns. The implementation of top-up operation is described, with a focus on the simultaneous achievement of stability of stored current, beam orbit, purity of an isolated single bunch, and beam injection efficiency. Stored-current fluctuations have been routinely reduced to a level of 10(-3). Stored-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Synchrotron Radiation

سال: 2011

ISSN: 0909-0495

DOI: 10.1107/s0909049511042518