Automatic Melting Point Apparatus with Air Bath Furnace
نویسندگان
چکیده
منابع مشابه
A melting-point-of gallium apparatus for thermometer calibration.
We have investigated the equilibrium melting point of gallium as a temperature fixed-point at which to calibrate small thermistor thermometers, such as those used to measure temperature in enzyme reaction analysis and other temperature-dependent biological assays. We have determined that the melting temperature of "6N" (99.999% pure) gallium is 29.770 +/- 0.002 degrees C, and that the constant-...
متن کاملParallel Simulation of an Ash Melting Furnace
We determine the distribution of heat uxes of a furnace for burning ash via a simulation of a heat transfer problem. With paralleliza-tion of the problem this task can be done faster. Within the volume of the furnace, heat transfer is dominated by radiation, where heat conduction through the walls is important. Our mathematical model leads to a system of polynomials and the problem is reduced t...
متن کاملA versatile nematode water bath apparatus.
T h e activity of nematodes in unstirred water frequently decreases due to the depletion of oxygen from their surrounding microenvironment (1,2,3,). In in vitro studies on the activity of Nothanguina phyllobia T h o r n e we found it essential to prevent this by constantly agitating nematode suspensions. Various physiological processes are undoubtedly affected at oxygen tensions which inhibit a...
متن کاملMelting Point Determination
An improved technique is described for the accurate determination of melting points of metals in the temperature range 1500° to 2500°C. The improvements consist of gradient heating and refinements in cavity preparation to obtain true black-body conditions. The melting point of hafnium, as determined by this method, is set a t 22220-+30°C. This is over 200°C higher than one of the values reporte...
متن کاملA graphic prothrombin time recorder with air bath.
An air bath is described which maintains plasma, reagents, and glassware at constant temperature. Within this bath is a variable light source, without filters, from which light passes through the liquid mixture of plasma and reagents (0.3-mi. volume) to a photoelectric cell. The output of the cell is fed into a Speedomax recorder. Addition of reagents and time of clotting show clearly on the re...