Automatic Isocenter Validation via Radioluminescent Phantoms for Precision SRS/SBRT

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric validation for an automatic brain metastases planning software using single‐isocenter dynamic conformal arcs

An automatic brain-metastases planning (ABMP) software has been installed in our institution. It is dedicated for treating multiple brain metastases with radiosurgery on linear accelerators (linacs) using a single-setup isocenter with noncoplanar dynamic conformal arcs. This study is to validate the calculated absolute dose and dose distribution of ABMP. Three types of measurements were perform...

متن کامل

Digital perfusion phantoms for visual perfusion validation.

OBJECTIVE Despite the increasingly broad use of perfusion applications, we still have no generally accessible means for their verification: The common sense of perfusion maps and "bona fides" of perfusion software vendors remain the only grounds for acceptance. Thus, perfusion applications are one of a very few clinical tools considerably lacking practical objective hands-on validation. MATER...

متن کامل

Designing microarray phantoms for hyperspectral imaging validation

The design and fabrication of custom-tailored microarrays for use as phantoms in the characterization of hyperspectral imaging systems is described. Corresponding analysis methods for biologically relevant samples are also discussed. An image-based phantom design was used to program a microarrayer robot to print prescribed mixtures of dyes onto microscope slides. The resulting arrays were image...

متن کامل

Algorithm validation using multicolor phantoms

We present a framework for hyperspectral image (HSI) analysis validation, specifically abundance fraction estimation based on HSI measurements of water soluble dye mixtures printed on microarray chips. In our work we focus on the performance of two algorithms, the Least Absolute Shrinkage and Selection Operator (LASSO) and the Spatial LASSO (SPLASSO). The LASSO is a well known statistical metho...

متن کامل

Quality Assurance, Accuracy, Precision and Phantoms

When an instrument such as an MRI scanner is installed and handed over to the user, a series of acceptance tests is often carried out by the customer (Och et al., 1992; McRobbie and Quest, 2002; Och et al., 1992). The vendor’s installation engineer will also have carried out extensive testing, according to the manufacturer’s protocols, using phantoms (test objects), to ensure the instrument is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Radiation Oncology*Biology*Physics

سال: 2017

ISSN: 0360-3016

DOI: 10.1016/j.ijrobp.2017.06.2226