Automatic infrasonic signal detection using the Hough transform
نویسندگان
چکیده
منابع مشابه
RfLPP-Hough Transform for Chirp Signal Detection
In this paper, the reassigned local polynomial periodogram along the frequency direction (RfLPP) is shown to be able to perfectly localize the chirp signal. Due to this property, the RfLPP is combined with the Hough transform for chirp signal detection in the parameter domain. Simulations of the RfLPP-Hough transform are given for chirp signal detection in white Gaussian noise and impulsive noi...
متن کاملAutomatic fault surface detection by using 3D Hough transform
Detection of faults plays an important role in the characterization of reservoir regions. In this paper, we propose an automatic fault surface detection method using 3D Hough transform to improve the interpretation efficiency. We first highlight the likely fault points in seismic data by thresholding the corresponding discontinuity volumes. Then, we apply 3D Hough transform to detect the likely...
متن کاملAutomatic Mango Detection Using Texture Analysis and Randomised Hough Transform
This paper presents a method of detecting overlapping mango fruits from the complex background image. This research uses image that is obtained from a digital camera. This method is based on pre-processing the input image using the texture analysis to determine the boundary of each overlapping fruits. The image is processed to determine the actual boundary, converted to binary images, and utili...
متن کاملEllipse Detection using the Hough Transform
We consider the problem of detecting elliptical curves using Hough Transform methods. Storage and efficiency problems are overcome by decomposing the problem into two stages. The first stage uses a novel constraint as the basis for a Hough Transform to detect the ellipse center while the second stage finds the remaining parameters using a simple but efficient focussing implementation of the HT....
متن کاملDetection of Microaneurysms in Retinal Angiography Images Using the Circular Hough Transform
This paper presents an automated method for detecting microaneurysms in the retinal angiographic images by using image processing techniques. In the presented method, in order to fade or remove the pseudo images, first retinal images are pre-processed. Then microaneurysms are identified by circular Hough transform. In the existing methods of dete...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Geophysical Research
سال: 2008
ISSN: 0148-0227
DOI: 10.1029/2008jd009822