Automatic inductive voltage divider bridge for operation from 10 Hz to 100 kHz
نویسندگان
چکیده
منابع مشابه
A Two-stage Inductive Voltage Divider for Coaxial Bridges
The traceability chain to derive the capacitance unit from the quantum Hall resistance coaxial bridges. These bridges employ a inductive voltage divider to provide the voltage ratio needed. One such divider has recently been constructed calibrated at Inmetro. The design techniques responsible for the small ratio errors of the device are detailed
متن کاملGuidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz).
This is a joint response from health care professional bodies within the UK. The response collates detailed information provided by the British Institute of Radiology (BIR), Institute of Physics and Engineering in Medicine (IPEM), the Royal College of Radiologists (RCR), the Society and College of Radiographers (CSoR), the British Chapter of the International Society of Magnetic Resonance in Me...
متن کاملBinary Versus Decade Inductive Voltage Divider Comparison and Error Decomposition
Absbacl-An automatic Inductive Voltage Divider ( I M ) characterization method that can measure linearity by comparing WD’s with differeut structures is suggested. Structural models are employed to decompose an error vector into components that represent each divider. Initial tests at 400 Hz show that it is possible to assign independent errors due to the binary and decade structures with a 27 ...
متن کاملThe Electromagnetic Radiation from Lightning in the Interval of 10 Khz to 100 Mhz
Average amplitude spectra are presented for large radiation impulses from the initial stage of 15 cloud-to-ground (CG) and 36 intracloud (IC) lightning discharges. The spectra are obtained by Fourier transformation of the time domain records of lightning radiation fields with wide bandwidth devices. The field records include the electric field change ∆E (bandwidth 0 –500 kHz), the electric fiel...
متن کاملA Capacitance Measurement System Using an IVD Bridge
A new system to characterize the magnitude and phase characteristics of 1 pF to 1 F capacitance standards over the 50 Hz to 100 kHz frequency range is described. The system has been developed to provide measurement support for LCR meters and general impedance measurement services. It consists of an inductive voltage divider (IVD) bridge capable of accurately comparing two capacitance standards...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Instrumentation and Measurement
سال: 1993
ISSN: 0018-9456
DOI: 10.1109/19.278535